CHAPTER 4: SETPOINTS
ELEMENT
OPERANDS
Phase TOC
Ph TOC 1 PKP A
Ph TOC 1 PKP B
Ph TOC 1 PKP C
Ph TOC 1 PKP
Ph TOC 1 OP A
Ph TOC 1 OP B
Ph TOC 1 OP C
Ph TOC 1 OP
Ph TOC 2
Phase IOC
Ph IOC 1 PKP A
Ph IOC 1 PKP B
Ph IOC 1 PKP C
Ph IOC 1 PKP
Ph IOC 1 OP A
Ph IOC 1 OP B
Ph IOC 1 OP C
Ph IOC 1 OP
Ph IOC 2 OP
Phase Directional OC
Ph Dir OC REV A
Ph Dir OC REV B
Ph Dir OC REV C
Ph Dir OC REV
Phase Reversal
Phase Rev PKP
Phase Rev OP
Phase Rev Inhibit
Phase UV
Ph UV 1 PKP
Ph UV 1 PKP A
Ph UV 1 PKP B
Ph UV 1 PKP C
Ph UV 1 OP
Ph UV 1 OP A
Ph UV 1 OP B
Ph UV 1 OP C
Ph UV 2
Phase OV
Ph OV 1 PKP
Ph OV 1 PKP A
Ph OV 1 PKP B
Ph OV 1 PKP C
Ph OV 1 OP
Ph OV 1 OP A
Ph OV 1 OP B
Ph OV 1 OP C
Ph OV 2
Power Factor
PF Trip PKP
PF Trip OP
PF Alarm PKP
PF Alarm OP
Programmable
PB 1 ON
Pushbuttons
PB 1 OFF
Pushbuttons 2 and 3
Pulse Output
Pos Wthrs Pulse OP
Neg Wthrs Pulse OP
Pos Varh Pulse OP
Neg Varh Pulse OP
Reactive Power
Pos var Alrm PKP
Pos var Alrm OP
Neg var Alrm PKP
Neg var Alrm OP
Pos var Trip PKP
Pos var Trip OP
Neg var Trip PKP
Neg var Trip OP
Reduced Voltage Start
Reduced Volt Ctrl
Reduced Volt Fail
869 MOTOR PROTECTION SYSTEM – INSTRUCTION MANUAL
EVENT DESCRIPTION
Phase A of phase time overcurrent 1 has picked up
Phase B of phase time overcurrent 1 has picked up
Phase C of phase time overcurrent 1 has picked up
At least one phase of phase time overcurrent 1 has picked up
Phase A of phase time overcurrent 1 has operated
Phase B of phase time overcurrent 1 has operated
Phase C of phase time overcurrent 1 has operated
At least one phase of phase time overcurrent 1 has operated
The same set of operands as per Phase TOC 1
Phase A of phase IOC 1 has picked up
Phase B of phase IOC 1 has picked up
Phase C of phase IOC 1 has picked up
At least one phase of phase IOC overcurrent 1 has picked up
Phase A of phase IOC 1 has operated
Phase B of phase IOC 1 has operated
Phase C of phase IOC 1 has operated
At least one phase of phase IOC 1 has operated
The same set of operands as per Phase IOC 1
Phase A current in reverse direction
Phase B current in reverse direction
Phase C current in reverse direction
At least one phase current in reverse direction
The phase reversal element has picked up
The phase reversal element has operated
The phase reversal start inhibit occurs
At least one phase of phase undervoltage 1 has picked up
Phase A of phase undervoltage 1 has picked up
Phase B of phase undervoltage 1 has picked up
Phase C of phase undervoltage 1 has picked up
At least one phase of phase undervoltage 1 has operated
Phase A of phase undervoltage 1 has operated
Phase B of phase undervoltage 1 has operated
Phase C of phase undervoltage 1 has operated
The same set of operands as per Phase UV 1
At least one phase of phase overvoltage 1 has picked up
Phase A of phase overvoltage element 1 has picked up
Phase B of phase overvoltage element 1 has picked up
Phase C of phase overvoltage element 1 has picked up
At least one phase of phase overvoltage 1 has operated
Phase A of phase overvoltage element 1 has operated
Phase B of phase overvoltage element 1 has operated
Phase C of phase overvoltage element 1 has operated
The same set of operands as per Phase OV 1
The power factor (trip) has pickup up
The power factor (trip) has operated
The power factor alarm has picked up
The power factor alarm has operated
Pushbutton 1 ON state has been asserted
Pushbutton 1 OFF state has been asserted
The same set of operands as shown for Pushbutton 1
Positive Watthours pulse occurs at the end of the programed energy
increment.
Negative Watthours pulse occurs at the end of the programed energy
increment.
Positive VARhours pulse occurs at the end of the programed energy
increment.
Negative VARhours pulse occurs at the end of the programed energy
increment.
Positive var alrm stage has picked up
Positive var alrm stage has operated
Negative var alrm stage has picked up
Negative var alrm stage has operated
Positive var trip stage has picked up
Positive var trip stage has operated
Negative var trip stage has picked up
Negative var trip stage has operated
Asserted for one second upon a valid transition in any mode
Asserted when an invalid transition occurs
FLEXLOGIC