3.1.2 Removing the front panel assembly
(See Figs.5 to 8)
• Prior to performing the following procedures, remove the side
panels L/R.
(1) From the right side of the main body, push the slide cam
and pull the tray out of the main body in the direction of the
arrow 1. (See Fig.5.)
(2) Remove the tray fitting from the tray in the direction of the
arrow 2. (See Fig.5.)
(3) From the both sides of the main body, remove the two
screws C attaching the front panel assembly. (See Figs.6
and 7.)
(4) Release the two claws c and claws d to draw out the front
panel assembly in the direction of the arrow. (See Figs.6
and 7.)
(5) From the right side of the main body, disconnect the card
wire from the connector
Fig.8.)
(6) Disconnect the wire from the connector
board. (See Fig.8.)
(7) Remove the front panel assembly in the direction of the ar-
row. (See Fig.8.)
Front panel assembly
2
1
Tray assembly
Slide cam
Tray fitting
C
d
Front panel assembly
1-8 (No.MB286)
CN730
on the main board. (See
CN270
on the main
Fig.5
c
Fig.6
c
d
Front panel assembly
Fig.7
Card wire
CN730
Wire
CN270
Front panel assembly
Fig.8
C
Main board