Daewoo DWF-7588TE Service Manual page 19

Programmable washing machine
Table of Contents

Advertisement

WATER LEVEL SENSOR UNIT
1) CIRCUIT DIAGRAM
M
I
R18,220Ω
C
24
O
M
2) EXPLANATION OF CIRCUIT
• Push the power switch. And, in order to carry on the action of course selection, input the selection of
frequency according to each water level selection.
• The frequency of water level sensor in each water level becomes square wave and is sended to the
MICOM.
WATER LEVEL NAME
FREQUENCY
WATER LEVEL
HIGH
22.52KHz
400±15
MIDDLE
23.04KHz
340+10, -15
LOW
23.56KHz
280±15
SMALL
24.05KHz
220±15
E.SMALL
24.33KHz
180±15
RESET
25.02KHz
60 ± 20
0
25.40KHz
If the water level is selected 'HIGH' in washing, water suppply proceeds until inputing the frequency 22.70
KHz of 'HIGH' in the MICOM terminal No. 24. Being finished the water supply, washing process is
proceeded. After the washing process, water level reaches to RESET point, and then after the (D) + 60
seconds, the spin process begins.
• The value of the frequency between the MICOM terminal No. 24 and the GND.
5.4V
0V
f=22~25KHz
3) CAUTION FOR A/S
• The output of the frequency in the WATER LEVEL SENSOR varies in accordance with temperature and
using condition. If it doesn't input the output of the WATER LEVEL SENSOR in the MICOM, the error
message is displayed as 'E9'. In case of proceeding the water supply continuously in 'HIGH' water level,
it is desirable to change the WATER LEVEL SENSOR because of the defect in the WATER LEVEL
SENSOR.
• Check the TR Q4(A1270Y)
• Being checked with tester, the value of the voltage reaches about 4V.
• As the frequency is low, the water level is higher.
R21,10KΩ
Q4
A1270
R22, 3.9KΩ
R20,10KΩ
DWF-7588
DWF-9288
DWF-1088
80L
98L
96L
68L
78L
81L
55L
61L
65L
42L
48L
49L
30.5L
33L
36L
KHz
32
ELECTRIC POWER SUPPLY UNIT
1) CIRCUIT DIAGRAM
D1,1N4003
16
C3 6
C13
C34
3300µF
470µF
104Z
10V
16V
2) EXPLANATION OF CIRCUIT
• The primary voltage of the transformer sets 220V, the secondary voltage of the transformer is full
wave rectified by use of the D7 (1N4003) & D8(1N4003).
1 The gray & red (The waveform in
secondary part of the transformer)
f=60Hz
Vpeak=11.4V
Vrms=8V
2 Measuring the wave form in case of the
removing condenser by the removal ripple
C33
12V
0V
3 It is removed the ripple with attaching the
C33(2200µF).
0V
REGULATOR
D8,1N4003
220V
7806
C32
C33
104Z
2200µF
35V
COMMON
D7,1N4003
4 The waveform of output in the
REGULATOR I.C 7806.
6V
0V
5 The waveform after passing the D2.
5.4V
0V
12V
33