Fujitsu B23Q8WD-G-01-J Hardware Manual page 24

Sparc enterprise servers for solaris operating system
Table of Contents

Advertisement

No.
CR ID
29
6518348
6536564
30
31
6539243
32
6620322
18
Description
Workaround
There is a note on using the standard Solaris fibre channel driver with the following host bus
adaptors.
Target Host Bus Adaptors
- XSEFC401AF
- XSEFC402AF
- XSEFC401AU
- XSEFC402AU
Panic may occur due to a path failure in a disk array device with fibre channel connection.
Apply the following patch.
125184-02 or later SunOS 5.10: Sun Fibre Channel Device Drivers
showlogs(8) and showstatus(8) command on XSCF might report wrong I/O component due to
wrong diagnosis by Solaris Fault management Architecture when faults in I/O devices occur.
Refer to "3.3Wrong I/O device FRU could be reported
This problem has been resolved by the following patch. After applying it, the workaround is no
longer needed.
125369-05 or later SunOS 5.10: Fault Manager patch
The following unexpected error message may be notified on SPARC Enterprise T1000/T2000
servers with Solaris OS 8/07 installed.
Sep 19 12:14:57 xxxx ldc: [ID xxxxxx kern.warning] WARNING: ldc: cannot
negotiate hypervisor LDC services group: 0x101 major: 1 minor: 0 errno: 22
This message is harmless and can be safely ignored.
This problem has been fixed by the following patch.
127127-11 or later SunOS 5.10: kernel patch
On SPARC Enterprise T5120/T5220 servers, if the system is using mirroring feature of
PRIMECLUSTER GDS, the system may panic while booting.
Apply the following patch.
127111-09 or later SunOS 5.10: kernel patch