Appendix.
RECEIVE Flow Chart & Solution
14-A) Check Placement of RECEIVER
14-B) Check F605, F606 Using Osciolloscope
Yes
Signal Detect ?
Goto Block 15!
GSM Handsets Lab.
No
85
Check Soldering
F605, F606
14-B) Test!!
Yes
Replace
U501
Reference RECEIVER Signal