Recognize an Under-Voltage Condition

If the system detects an under-voltage condition, it sends an alarm.
To recognize this condition, look for the following system message: .
This message indicates that the specified card is not receiving enough power. In response, the system first shuts down Power over
Ethernet (PoE). If the under-voltage condition persists, line cards are shut down, then the RPMs.

Troubleshoot an Under-Voltage Condition

To troubleshoot an under-voltage condition, check that the correct number of power supplies are installed and their Status light emitting
diodes (LEDs) are lit.
The following table lists information for SNMP traps and OIDs on the environmental monitoring hardware and hardware components.
Table 92. SNMP Traps and OIDs
OID String
Receiving Power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.6
Transmitting power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.8
Temperature
.1.3.6.1.4.1.6027.3.10.1.2.5.1.7
Hardware MIB Buffer Statistics
.1.3.6.1.4.1.6027.3.27.1.4
.1.3.6.1.4.1.6027.3.27.1.5
.1.3.6.1.4.1.6027.3.27.1.6

Buffer Tuning

Buffer tuning allows you to modify the way your switch allocates buffers from its available memory and helps prevent packet drops during a
temporary burst of traffic.
Dell Networking OS provides two pre-defined buffer profiles, one for single-queue (for example, non-quality-of-service [QoS]) applications,
and one for four-queue (for example, QoS) applications. You must reload the system for the global buffer profile to take effect, a message
976
Debugging and Diagnostics
OID Name
chSysPortXfpRecvPower
chSysPortXfpTxPower
chSysPortXfpRecvTemp
dellNetFpPacketBufferTable
dellNetFpStatsPerPortTable
dellNetFpStatsPerCOSTable
Description
OID displays the receiving power of the
connected optics.
OID displays the transmitting power of the
connected optics.
OID displays the temperature of the
connected optics.
NOTE:
These OIDs only generate if
you enable the enable optic-
info-update-interval is
enabled command.
View the modular packet buffers details per
stack unit and the mode of allocation.
View the forwarding plane statistics
containing the packet buffer usage per port
per stack unit.
View the forwarding plane statistics
containing the packet buffer statistics per
COS per port.