Section 5
I/O Settings and Control Methods
NOISE MEASUREMENT
Master Unit to DeviceNet Remote ID Controller
Signal
CMD0 to
CMD3
DeviceNet Remote ID Controller to Master Unit
Mode: 4-byte Access
Signal
NORM
ERR
XXX_ERR
R-DATA
Mode: 26-byte or 58-byte Access
Signal
NORM
ERR
XXX_ERR
R-DATA
Master Unit to DeviceNet Remote ID Controller Settings Example
15
*
CIO
+0
0
CIO
+1
0
CIO
+2
0
CIO
+3
RFID System
58
User's Manual
Bit length
Value
4
0111B
Bit length
Value
1
0 or 1
1
0 or 1
10
0 or 1
32
---
Bit length
Value
1
0 or 1
1
0 or 1
10
0 or 1
32
---
14
13
12
11
10
*
*
*
*
*
Change according to settings.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Description
NOISE MEASUREMENT
Description
Set to 1 when operation is ended normally.
Set to 1 if the command ends in an error.
The bit corresponding to error completion will be 1, and the error
details will be displayed.
Result of noise measurement
05 hex: Average noise level
04 hex: Maximum noise level
07 hex: Minimum noise level
06 hex: Always 00H
Description
Set to 1 when operation is ended normally.
Set to 1 if the command ends in an error.
The bit corresponding to error completion will be 1, and the error
details will be displayed.
Result of noise measurement
07 hex: Average noise level
06 hex: Maximum noise level
09 hex: Minimum noise level
08 hex: Always 00H
Bits
9
8
7
6
5
*
0
1
1
1
Fixed
NOISE MEASUREMENT
0
0
0
0
0
Fixed
0
0
0
0
0
Fixed
0
0
0
0
0
Fixed
4
3
2
1
0
1
0
0
0
0
Fixed
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Advertisement