Hitachi CP-X2511N Service Manual page 58

Hide thumbs Also See for CP-X2511N:
Table of Contents

Advertisement

CP-X2511N(C15I-25N2) / CP-X3011N(C15I-30N2) / CP-X4011N(C15I-40N2) / CP-X2011N(C15-20N2) / ED-X45N(C15-20N2)
2) Attach the Ballast Power Unit to the Ballast Holder.
Slide and insert the Ballast Power
Unit into the Ballast Holder so that
two corners of the circuit board are
held in the rib fi rmly.
3) Fasten the Ballast Power Unit to the Ballast Holder with a screw.
4) Fasten the insulating sheet to the Ballast Holder with 2 screws.
(Refer the chapter "Wiring diagram".)
4. Replacement of circuit power unit
When you replace the power unit (circuit), be sure to remove the ferrite core from the original power
unit (circuit) and attach to a new one.
Follow the instruction on page 39 because this assembling and wiring works are important for prod-
uct safety.
ATTENTION: Place the insulating sheet between the
View from opposite side
Ballast Holder and the Power Unit (Ballast) here.
Rib
Screw
58
Ballast Power Unit
Confirm that both corners of
the circuit board are put in
place as shown.
Place the insulating sheet
behind the rib of the Ballast
Holder.
GOOD
NG

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp-x3011nEd-x45nCp-x4011nCp-x2011n

Table of Contents