INTEGRATED FURNACE CONTROL (I.F.C.)
FIGURE 26
TWO-STAGE CLIMATE-TALK COMMUNICATING FURNACE CONTROL (RHEEM # 62-102784-01)
24 VAC THERMOSTAT
(TSTAT) INPUTS (J4 & J6)
24 VAC THERMOSTAT (TSTAT)
INPUTS (J4 & J6)
These connections are used with any
traditional 24VAC one-stage or two-
stage thermostat. Fully communicating
thermostats must be connected to the
COMM NETWORK CONNECTION
(see section titled C C O O M M M M U U N N I I C C A A T T I I N N G G
S S Y Y S S T T E E M M S S of this document for
details).
W W 1 1 , , W W 2 2 , , Y Y 1 1 , , Y Y 2 2 , , G G , , C C a a n n d d R R are the
traditional thermostat inputs used in
nearly all HVAC equipment. Installation
of the thermostat to these connections
is straight-forward and simple.
(all must be on)
H H U U M M S S T T A A T T – This terminal is used
to connect the output of a humidistat
to the furnace control to control
humidification and/or dehumidifica-
tion. Optional equipment is required
for these features. Please see the
section titled HUMIDIFICTION AND
DEHUMIDIFICATION of this docu-
ment for more details.