3. TROUBLESHOOTING GUIDE

3.1 OUTSIDE DIMENSIONS

3.2 PIPING SYSTEM

CONDENSER COIL
MOTOR
MUFFLER
Following is a brief description of the important components and their functions in the refrigeration system.
Refer to figure 19 to follow the refrigeration cycle and the flow of the refrigerant in the cooling cycle.
EVAPORATOR COILS
COOLED
AIR
675(770)
FAN
ROOM AIR CONDITIONER
CYCLE OF REFRIGERATION
COMPLETE LIQUID
BOIL OFF POINT
ROOM AIR HEAT LOAD
LIQUID
PRESSURE
DROP
(LIQUID REFRIGERANT)
CAPILLARY TUBE
VAPOR INLET
SUCTION LIME
COOL LOW PRESSURE VAPOR
OUTSIDE COOLING
AIR FOR REFRIGERANT
PASS THROUGH
MOTOR
COMPRESSOR
DRIER
OIL
Figure 19
—13—
660
DRIER
CAPILLARY TUBE
COMPRESSOR
MUFFLER
BLOWER
EVAPORATOR COIL
CONDENSER COILS
HOT
DISCHARGED
AIR
LIQUID OUTLET
HIGH PRESSURE VAPOR
LIQUID PEFRIGERANT
LOW PRESSURE VAPOR