Emerson Daniel 3812 Installation Manual

Liquid ultrasonic flow meter
Hide thumbs Also See for Daniel 3812:
Table of Contents

Advertisement

Quick Links

Installation Manual
P a r t N u m b e r 3 - 9 0 0 0 - 7 6 5 R e v i s i o n H
J u n e 2 0 1 7
Daniel
3812 Liquid Ultrasonic Flow Meter
TM
for Direct or Remote Mount Meter Electronics

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Daniel 3812

  • Page 1 Installation Manual P a r t N u m b e r 3 - 9 0 0 0 - 7 6 5 R e v i s i o n H J u n e 2 0 1 7 Daniel 3812 Liquid Ultrasonic Flow Meter for Direct or Remote Mount Meter Electronics...
  • Page 3 +971 4 8118100 +971 4 8865465 Email • Customer Service: Daniel.SystemSales@emerson.com • Customer Support: Daniel. SystemSales@emerson.com • Asia-Pacific: danielap.support@emerson.com • Europe: danielEMA.cst@emerson.com Return Material Authorization (RMA) A Return Material Authorization (RMA) number must be obtained prior to returning any equipment for any reason.
  • Page 4 Signal words and symbols Pay special attention to the following signal words, safety alert symbols and statements: Safety alert symbol This is a safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Danger indicates a hazardous situation which, if not avoided, will result in death or serious injury.
  • Page 5: Important Safety Instructions

    Important safety instructions Daniel Measurement and Control, Inc. (Daniel) designs, manufactures and tests products to function within specific conditions. Because these products are sophisticated technical instruments, it is important that the owner and operation personnel strictly adhere both to the information printed on the product and to all instructions provided in this manual prior to installation, operation, and maintenance.
  • Page 6 Product Operation Personnel: • To prevent personal injury, personnel must follow all instructions of this manual prior to and during operation of the product. • Follow all warnings, cautions, and notices marked on, and supplied with, this product. • Verify that this is the correct instruction manual for your Daniel product. If this is not the correct documentation, contact Daniel at 1-713-827-6314.
  • Page 7 Notice THE CONTENTS OF THIS PUBLICATION ARE PRESENTED FOR INFORMATIONAL PURPOSES ONLY, AND WHILE EVERY EFFORT HAS BEEN MADE TO ENSURE THEIR ACCURACY, THEY ARE NOT TO BE CONSTRUED AS WARRANTIES OR GUARANTEES, EXPRESSED OR IMPLIED, REGARDING THE PRODUCTS OR SERVICES DESCRIBED HEREIN OR THEIR USE OR APPLICABILITY. ALL SALES ARE GOVERNED BY DANIEL'S TERMS AND CONDITIONS, WHICH ARE AVAILABLE UPON REQUEST.
  • Page 8 Warranty and Limitations 1. LIMITED WARRANTY: Subject to the limitations contained in Section 2 herein, Daniel Measurement & Control, Inc. ("Daniel") warrants that the licensed firmware embodied in the Goods will execute the programming instructions provided by Daniel, and that the Goods manufactured by Daniel will be free from defects in materials or workmanship under normal use and care and Services will be performed by trained personnel using proper equipment and instrumentation for the particular Service provided.
  • Page 9: Table Of Contents

    Typical Applications ..................1 Features and benefits .................. 2 Acronyms, abbreviations and definitions ............3 Daniel MeterLink software ................5 Daniel 3812 Liquid Ultrasonic Flow meter design ........... 6 Meter specifications ................. 13 Pre-installation considerations ..............17 Safety ...................... 17 Daniel 3812 Certifications and Approvals ............
  • Page 10 Using a Field Communicator to configure the meter ........95 Security seals for the meter ................ 98 Appendix A: Engineering drawings Daniel 3812 Liquid Ultrasonic Flow Meter drawings ............99 Appendix B: Open source licenses GNU General Public License..................... 102 GNU Lesser General Public License ..................
  • Page 11 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Installation Manual List of Tables 3-9000-765 Rev H June 2017 List of Tables Table 1-1 Acronyms, abbreviations and definitions ................3 Table 1-2 Meter specifications......................13 Table 2-1 3812 Ultrasonic Meter shrouds options per ANSI pressure rating ........29 Table 2-2 Piping recommendation for uni-directional or bi-directional flow ........
  • Page 12 List of Tables Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Installation Manual June 2017 3-9000-765 Rev H List of Tables...
  • Page 13 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Installation Manual List of Figures 3-9000-765 Rev H June 2017 List of Figures Figure 1-1 Daniel MeterLink download and registration ..............5 Figure 1-2 Direct mount electronics assembly with split shroud ............ 6 Figure 1-3 Direct mount electronics with latched single band shrouds and remote display....
  • Page 14 List of Figures Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Installation Manual June 2017 3-9000-765 Rev H Figure 3-14 Split shroud security seals ................... 70 Figure 3-15 Latched band shroud assembly ................... 71 Figure 3-16 Shroud latch holes for security wire seals..............72 Figure 4-1 AMS Device Description search ...................
  • Page 15: Typical Applications

    June 2017 Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meters have direct mount or remote mount electronic options and various configurations that meet a broad range of customer requirements. Each meter comes fully assembled from Daniel Measurement and Control, Inc. and all parts and assemblies are tested prior to shipment.
  • Page 16: Features And Benefits

    Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Features and benefits • Explosion-proof transmitter electronics enclosure with CPU Module, Power Supply, Intrinsic Safety Barrier Module • Intrinsically safe transducer electronics enclosure with the Acquisition Module •...
  • Page 17: Acronyms, Abbreviations And Definitions

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev H June 2017 Acronyms, abbreviations and definitions Table 1-1 Acronyms, abbreviations and definitions Acronym or abbreviation Definition ° degree (angle) degrees celsius (temperature unit) degrees fahrenheit (temperature unit)
  • Page 18 Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Table 1-1 Acronyms, abbreviations and definitions Acronym or abbreviation Definition meter (length unit) cubic meters per day (volumetric flow rate) cubic meters per hour (volumetric flow rate)
  • Page 19: Rev H June

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev H June 2017 Table 1-1 Acronyms, abbreviations and definitions Acronym or abbreviation Definition watts (power unit) Acronyms, abbreviations and definitions...
  • Page 20: Daniel Meterlink Software

    Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Daniel MeterLink software Daniel MeterLink software has robust features for setting communications parameters, calibrating your meter, collecting logs and reports and monitoring the meter health and alarm statuses.
  • Page 21: Daniel 3812 Liquid Ultrasonic Flow Meter Design

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev H June 2017 Refer to the Daniel MeterLink Software for Gas and Liquid Ultrasonic Meters Quick Start Manual (P/N 3-9000-763) for installation instructions and setup for initial communications. You may download the manual from the Daniel MeterLink web page: http://www2.emersonprocess.com/en-US/brands/daniel/Flow/ultrasonics/Pages/MeterLink.aspx...
  • Page 22: Figure 1-3 Direct Mount Electronics With Latched Single Band Shrouds And Remote Display

    Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Figure 1-3 Direct mount electronics with latched single band shrouds and remote display A. Explosion-proof transmitter enclosure (CPU Module, Power Supply, I.S. Barrier Board, Backplane board, and optional LCD Board with glass endcap) B.
  • Page 23: Figure 1-4 Direct Mount Electronics With Bolted Single Band Shrouds And Local Display

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev H June 2017 Figure 1-4 Direct mount electronics with bolted single band shrouds and local display A. Explosion-proof transmitter enclosure (CPU Module, Power Supply, I.S. Barrier Board, Backplane board, and optional LCD Board with glass endcap) B.
  • Page 24: Figure 1-5 Direct Mount Electronics Assembly With Clamped Band Shrouds

    Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Figure 1-5 Direct mount electronics assembly with clamped band shrouds A. Explosion-proof transmitter enclosure (CPU Module, Power Supply, I.S. Barrier Board, Backplane board, optional LCD Board with glass endcap) B.
  • Page 25: Figure 1-6 Remote Mount Electronics Assembly With Clamped Band Shrouds

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev H June 2017 Figure 1-6 Remote mount electronics assembly with clamped band shrouds A. Explosion-proof transmitter enclosure (CPU Module, Power Supply, I.S. Barrier Board, Backplane board, and optional LCD Board with glass endcap) B.
  • Page 26: Figure 1-7 Remote Mount Electronics Assembly With Split Shrouds

    Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Figure 1-7 Remote mount electronics assembly with split shrouds A. Explosion-proof transmitter enclosure (CPU Module, Power Supply, I.S. Barrier Board Backplane board, optional LCD Board with glass endcap) B.
  • Page 27: Figure 1-8 Optional Local Display And Glass Endcap

    June 2017 Figure 1-8 Optional local display and glass endcap The Daniel 3812 Liquid Ultrasonic Flow Meter is a two-path (four transducers) in-line meter designed to measure the difference in signal transit time with and against the flow across one or more measurement path(s).
  • Page 28: Meter Specifications

    Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Meter specifications ESCAPING FLUIDS HAZARD The purchaser of the meter is responsible for the selection of Daniel components/seals and materials compatible with the chemical properties of the measurement fluid.
  • Page 29 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev H June 2017 Table 1-2 Meter specifications Body and Flange Pressure U.S. Customary Units sizes - 2, 3, 4, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28, 30, and 36 (in) rating range •...
  • Page 30 Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Table 1-2 Meter specifications • Transducers LT-10 and LT-11 Operating temperature range with NBR O-rings F to +275 F (-50 C to 135 •...
  • Page 31 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev H June 2017 Table 1-2 Meter specifications Frequency/Digital The meter has user-configurable selections for either a frequency output or Digital status (FODO) Output(s) see Section 3.6.1 (Also (3) Frequency/Digital Outputs •...
  • Page 32: Pre-Installation Considerations

    • Data collection and retention procedures Safety The Daniel 3812 Liquid Ultrasonic Flow Meter is suitable for use in U.L. Class 1, Division 1, Group C and D hazardous locations. DANGER TO PERSONNEL AND EQUIPMENT Observe all precautionary labels posted on the equipment and safety messages throughout the meter documentation.
  • Page 33 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev H June 2017 Daniel 3810 Series Liquid Ultrasonic Meters are INMETRO certified. Refer to the 3810 Series Liquid Ultrasonic Flow Meter Tag, INMETRO Certification drawing DMC - 006173.
  • Page 34: Daniel 3812 Certifications And Approvals

    Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Daniel 3812 Certifications and Approvals Daniel 3810 Series Liquid Ultrasonic Flow Meters have electrical, metrology, intrinsic safety and Pressure Equipment Directive certifications, approvals and lab testing and calibration certifications by the agencies listed below.
  • Page 35: Section 2: Mechanical Installation

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation 3-9000-765 Rev H June 2017 Section 2: Mechanical installation Meter piping, lifting and mounting Refer to the following sections for piping recommendations, lifting with hoist rings and slings, mounting in heated or cooled pipelines and safety warnings and precautions.
  • Page 36 Section 2: Mechanical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H CRUSHING HAZARD Do not remove flange stabilizers. Attempting to do so may allow the meter to roll, resulting in serious injury or equipment damage.
  • Page 37 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation 3-9000-765 Rev H June 2017 Meter components FLUID CONTENTS MAY BE UNDER PRESSURE When the meter is under pressure, DO NOT attempt to remove or adjust the transducer housing.
  • Page 38: Figure 2-1 Direct Mount Meter Electronics Assembly With Split Shroud

    Section 2: Mechanical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Daniel Liquid Ultrasonic Flow Meters are assembled, configured, and tested at the factory. The meter components include the transmitter electronics enclosure, the base electronics enclosure, the meter body with shroud covers for the transducers and cable assemblies and a direct or remote mount option.
  • Page 39: Figure 2-2 Remote Mount Meter Electronics Assembly With Split Shroud

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation 3-9000-765 Rev H June 2017 Figure 2-2 Remote mount meter electronics assembly with split shroud A. Remote mount explosion-proof transmitter enclosure (CPU Module, Power Supply, I.S. I.S. Barrier Board, Backplane Board and optional LCD Display Board) B.
  • Page 40: Figure 2-3 Direct Mount Meter Electronics With Bolted Band Shrouds

    Section 2: Mechanical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Figure 2-3 Direct mount meter electronics with bolted band shrouds A. Explosion-proof transmitter enclosure (CPU Module, Power Supply, I.S. Barrier Board, Backplane Board and optional LCD Board with glass endcap) B.
  • Page 41: Table 2-1 3812 Ultrasonic Meter Shrouds Options Per Ansi Pressure Rating

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation 3-9000-765 Rev H June 2017 Figure 2-4 Direct mount meter electronics assembly with clamped band shrouds A. Explosion-proof transmitter enclosure (CPU Module, Power Supply, I.S. Barrier Board and Backplane Board) B.
  • Page 42: Piping Recommendations

    Section 2: Mechanical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Piping recommendations BURST HAZARD Before pipeline cleaning and maintenance (“pigging operations”), remove straightening vanes or flow conditioners. Failure to do so may cause excessive pressure in the meter system, resulting in serious injury/ death or equipment damage.
  • Page 43: Figure 2-5 Piping Recommendations Unidirectional Flow

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation 3-9000-765 Rev H June 2017 Sunshields, provided by the customer, may be required to prevent exceeding the process fluid temperature when the meter is mounted in a location with extremely hot climates.
  • Page 44: Figure 2-6 Piping Recommendations Bidirectional Flow

    Section 2: Mechanical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Figure 2-6 Piping recommendations bidirectional flow All pipe lengths are minimum: • D = Nominal pipe size in inches (i.e. 6" pipe size; 10 D = 60 in) •...
  • Page 45: Table 2-2 Piping Recommendation For Uni-Directional Or Bi-Directional Flow

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation 3-9000-765 Rev H June 2017 Meter tube dimensions with tube bundle or profiler plate for uni-directional and bi-directional flow, the minimum straight pipe length is as follows: Table 2-2 Piping recommendation for uni-directional or bi-directional flow...
  • Page 46: Meter Safety For Hoist Rings And Lifting Slings

    Failure to do so could allow the meter to roll, resulting in serious injury or equipment damage. Prior to lifting the unit, refer to the Daniel 3812 Liquid Ultrasonic Flow Meter nameplate or outline dimensional (general arrangement) drawing for the assembled weight.
  • Page 47: Use Of Appropriate Safety Engineered Swivel Hoist Rings In Meter End Flanges

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation 3-9000-765 Rev H June 2017 When lifting a Daniel Ultrasonic Meter by itself, Daniel recommends two methods. These methods are: • Using appropriately rated Safety Engineered Swivel Hoist Rings installed in the Daniel Ultrasonic Meter end flanges.
  • Page 48: Figure 2-8 Safety Approved Hoist Ring And Non-Compliant Eye Bolt

    Section 2: Mechanical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Figure 2-8 Safety approved hoist ring and non-compliant eye bolt Safety engineered swivel hoist ring Eye bolt Safety precautions using safety engineered swivel hoist rings...
  • Page 49: Figure 2-9 90 Degree Angle Between Slings

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation 3-9000-765 Rev H June 2017 Always use separate slings for each hoist ring. NEVER reeve one sling through both hoist rings. The slings must be of equal length. Each sling must have a load rating that equals or exceeds the hoist ring load rating.
  • Page 50: Figure 2-10 Sling Contacting Electronics Enclosure

    Section 2: Mechanical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Direct mount option: NEVER allow the slings to contact the electronics enclosure. Damage to the enclosure may occur. Use a spreader bar with the slings to prevent...
  • Page 51 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation 3-9000-765 Rev H June 2017 Remote mount option: Always use separate slings for each hoist ring. NEVER reeve one sling through both hoist rings. The slings must be of equal length. Each sling must have a load rating that equals or exceeds the hoist ring load rating.
  • Page 52 Section 2: Mechanical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H NEVER apply shock loads to the meter. Always lift the meter gradually. If shock loading ever occurs, the hoist ring must be inspected per manufacturer's recommendations prior to be placed in any further service.
  • Page 53: Table 2-3 Hoist Ring Part Number Lookup Table

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation 3-9000-765 Rev H June 2017 How to obtain safety engineered swivel hoist rings A list of approved manufacturers of safety engineered hoist rings is below: • American Drill Bushing Company( www.americandrillbushing.com...
  • Page 54: Appropriately Rated Lifting Slings

    The following instructions are intended to provide general guidelines for proper lifting slings of the Daniel 3812 Ultrasonic meter by itself. These instructions are intended to be followed in addition to your company's standards or the DOE-STD-1090-2004 Hoisting and Rigging standard if such company standards do not exist.
  • Page 55: Figure 2-11 Correct Sling Attachment

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation 3-9000-765 Rev H June 2017 NEVER attempt to lift the meter using only one sling around the meter. Always use two slings wrapped around each end of the body as shown below. A choker style sling is recommended using a spreader bar.
  • Page 56: Figure 2-12 Incorrect Sling Attachment

    Section 2: Mechanical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H NEVER allow the slings to contact the electronics enclosure or the transducer shrouds. Damage to the meter may occur. If the slings do come in contact with the electronics or...
  • Page 57: Mounting Requirements In Heated Or Cooled Pipelines

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation 3-9000-765 Rev H June 2017 Mounting requirements in heated or cooled pipelines The ambient operating temperature of the 3812 Liquid Allocation electronics (i.e. Flameproof enclosure and Intrinsically safe base enclosure) is -40...
  • Page 58 Section 2: Mechanical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Mounting requirements in heated or cooled pipelines...
  • Page 59: Section 3: Electrical Installation

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation 3-9000-765 Rev H June 2017 Section 3: Electrical installation Cable length TTL mode The maximum cable length is 2000 feet when the “TTL” mode is selected. Cable length Open Collector mode For the “open collector”...
  • Page 60: Grounding Meter Electronics Housing

    3-9000-765 Rev H Grounding meter electronics housing Daniel 3812 Liquid Ultrasonic Flow Meter electronics should be internally grounded for intrinsically safe operations. Connect a wire to the chassis ground lug installed inside the Transmitter Electronics Enclosure as the primary ground. A secondary ground is located outside...
  • Page 61: Conduit Seals

    Figure 3-2 External ground lug A. External ground lug Conduit seals Daniel 3812 Liquid Ultrasonic Flow Meters require conduit seals for installations in hazardous environments. Adhere to safety instructions to protect personnel and equipment. HAZARDOUS VOLTAGE INSIDE Do not open the Transmitter Electronics Enclosure when an explosive gas atmosphere is present.
  • Page 62: Startup For Systems Using Explosion-Proof Conduit

    Section 3: Electrical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H 3.4.1 Startup for systems using explosion-proof conduit Assemble flexible conduit (recommended by Daniel) to the Transmitter Electronics Enclosure. A conduit seal fitting is required within 18 inches (457 mm) of the enclosure.
  • Page 63: Startup For Systems That Use Flame-Proof Cable

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation 3-9000-765 Rev H June 2017 3.4.2 Startup for systems that use flame-proof cable HAZARDOUS VOLTAGE INSIDE Do not open the Transmitter Electronics Enclosure when an explosive gas atmosphere is present.
  • Page 64: Wiring And I/O

    (i.e., 4-wire), or RS-232. Daniel MeterLink can communicate with multiple meters if they are multi-dropped using 4-wire full duplex RS-485 mode. The meter electronics are HART capable and provide communication flexibility with Daniel 3812 Liquid Ultrasonic Flow Meters. The HART® output provides communication with other field devices (e.g., 475/375 Field Communicator and AMS™...
  • Page 65: Cpu Module Labeling And Led Indicators

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation 3-9000-765 Rev H June 2017 3.5.1 CPU Module labeling and LED indicators The meter’s metrology mode and the status of the data transfer from the Acquisition Module to the CPU Module is indicated via light-emitting diode (LED) status indicators.
  • Page 66: Table 3-2 Cpu Module Labeling And Led Functions

    Section 3: Electrical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Table 3-2 CPU Module labeling and LED functions CPU Module switch Function Switch position indicator or LED WRITE PROT. • Switch position Write-protect mode - with switch in the ON •...
  • Page 67: Table 3-3 Ethernet Cable To Pc Communication

    After configuration of the meter, the DHCP option must be turned off if used on a LAN/WAN. RESTRICT ETHERNET AND SERIAL CONNECTIVITY USAGE Failure to restrict Ethernet and communication access to the Daniel 3812 Liquid Ultrasonic Flow Meter can result in, among other things, unauthorized access, system corruption, and/ or data loss.
  • Page 68: Table 3-4 Serial Port A Parameters

    Daniel MeterLink • 10 Mbps/100 Mbps Denotes auto-detected protocols. If not using Ethernet, a full duplex serial connection is necessary for Daniel MeterLink to communicate with a Daniel 3812 Liquid Ultrasonic Flow Meter. CPU Module labeling and LED indicators...
  • Page 69: I/O Connections

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation 3-9000-765 Rev H June 2017 Figure 3-4 PC to meter serial connection wiring DB-9 Connector Female I/O connections The meter provides the I/O connections on the CPU Module.
  • Page 70: Frequency/Digital Outputs

    Section 3: Electrical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H 3.6.1 Frequency/Digital outputs The meter has three user-configurable selections for configuring either a Frequency output or Digital output (FODO). • FODO1 (eight possible parameter configurations) [Type 2] [Type 4] •...
  • Page 71 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation 3-9000-765 Rev H June 2017 • Digital output 2A is based on Digital output 2A content (Frequency Output 2 Validity and Flow Direction) • Digital output 2B is based on Digital output 2B content (Frequency Output 2 Validity and...
  • Page 72: Table 3-5 Frequency/Digital Outputs Possible Configurations

    Section 3: Electrical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Table 3-5 Frequency/Digital Outputs possible configurations Frequency/Digital output Source configuration Frequency /Digital Output 1 • Frequency output 1A Frequency /Digital Output 2 •...
  • Page 73 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation 3-9000-765 Rev H June 2017 Figure 3-7 CPU Module - Frequency/Digital outputs common ground - Type 4 A. FODO 1 and DI1/FODO6 - shared common ground - Type 4 CPU Module (Group1) B.
  • Page 74: Analog Input Settings

    3.6.4 Digital Input The Daniel 3812 Liquid Ultrasonic Flow Meter provides one digital input that can be used as a general purpose input or used for synchronizing calibration (for flow calibration gating - contact closure). The meter records the volume seen between switch closures. The polarity of the input is configured as normal or inverted polarity.
  • Page 75: Configuration Protect Switch Settings

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation 3-9000-765 Rev H June 2017 3.6.6 Configuration protect switch settings The meter’s configuration parameters and firmware can be protected against changes via CPU Module Write PROT. switch as follows:...
  • Page 76: Security Seal Installation

    Security seal installation Security seals protect the integrity of the meter metrology and prevent tampering with transducer assemblies. The following sections detail how to properly seal the Daniel 3812 Liquid Ultrasonic Flow Meter after commissioning. The security seal wires are commercially available.
  • Page 77 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation 3-9000-765 Rev H June 2017 Procedure Rotate the end cap clockwise fully closing and compressing the end cap seal. Install the Security latch using a 3mm Allen wrench.
  • Page 78: Base Enclosure Security Seals

    Section 3: Electrical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H 3.7.2 Base Enclosure Security Seals Use the following instructions to install the security seal wire on the Base Enclosure. Procedure Install security wire seal into and through two of the four the holes in the socket head screws on the Base Enclosure cover (maximum wire diameter .078 inch;...
  • Page 79: Seal The Junction Box Remote Mount Electronics Option

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation 3-9000-765 Rev H June 2017 3.7.3 Seal the Junction Box remote mount electronics option Use the following instructions to install the security seal wire on the junction box, if required.
  • Page 80: Bolted Band Shroud Security Seals

    Section 3: Electrical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H 3.7.4 Bolted band shroud security seals If required, use the following instructions to install bolted band shrouds security wire seals. Figure 3-13 Bolted band shroud security seals - bottom view A.
  • Page 81: Clamped Band Shroud Security Seals

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation 3-9000-765 Rev H June 2017 Procedure Beneath the meter, install the security wires into and through the left front bolt (Item B) and feed through the holes in the right back bolt (Item D).
  • Page 82: Split Shroud Security Seals

    Section 3: Electrical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H 3.7.6 Split shroud security seals Use the following instructions to install the security seal wires on the split shroud covering the meter body and transducer assemblies.
  • Page 83: Latched Band Shroud Security Seals

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation 3-9000-765 Rev H June 2017 3.7.7 Latched band shroud security seals Use the following instructions to install the security seal wires on the latched band shrouds covering the meter body and transducer assemblies.
  • Page 84 Section 3: Electrical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Procedure Install the security seal wire into and through the holes in one of the shroud latches (maximum wire diameter .078 inch; 2.0 mm).
  • Page 85: Seal Conduit Ports

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation 3-9000-765 Rev H June 2017 3.7.8 Seal conduit ports The unit should be properly sealed with a sealing compound after electrical connections have been tested according to the customer's Best Practices schedule. Some areas require a witnessed Acceptance Test for the installed system and require that the meter run for a predetermined length of time (approximately one to two weeks) before the unit is sealed.
  • Page 86 Section 3: Electrical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Seal conduit ports...
  • Page 87: Section 4: Configuration

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 Section 4: Configuration After the mechanical and electrical installation is complete and connectivity is established, use the Daniel MeterLink Software for Gas and Liquid Ultrasonic Meters Quick Start Manual (P/N 3-9000-763) to setup initial communications with the meter.
  • Page 88: Field Setup Wizard

    Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Field Setup Wizard Use the Field Setup Wizard-Startup Page and select the checkboxes that allow proper configuration for your meter (Temperature, Pressure, Meter Corrections, and Meter Outputs).
  • Page 89: Table 4-1 Local Display Labels, Descriptions And Valid Units

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 Display Items The valid labels, descriptions and units for the shown below: Table 4-1 Local display labels, descriptions and valid units Local Display labels, descriptions and units QFLOW —...
  • Page 90 Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Table 4-1 Local display labels, descriptions and valid units Local Display labels, descriptions and units TOTVL — Reverse uncorrected volume • -BBL – Barrels •...
  • Page 91 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 Table 4-1 Local display labels, descriptions and valid units Local Display labels, descriptions and units AO2 — Analog Output 2 current • MA – Milliamperes...
  • Page 92 Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Display units The Meter volume units displayed are either U.S. Customary or Metric. To modify the Display Units, configure the Meter units system in the Field Setup Wizard — General Page.
  • Page 93: Using Ams Device Manager To Configure The Meter

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 Using AMS Device Manager to configure the meter This procedure assumes you have AMS Device Manager installed on the host computer and have downloaded the latest Daniel Liquid Ultrasonic Meter Device Description (DD).
  • Page 94: Figure 4-1 Ams Device Description Search

    Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Figure 4-1 AMS Device Description search Click Search Now Click the hyperlink. The file download dialog Daniel Industries Liquid 3810 Series Rev 1 displays. Click the button to save the files to your host system.
  • Page 95: Figure 4-2 Ams File Download Complete

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 AMS file download options button to complete the file download. Click the Save Figure 4-2 AMS file download complete Click to view the downloaded files.
  • Page 96: Figure 4-3 Ams Device Manager

    Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Click the Configure tab, and then select Guided Setup Manual Setup Alert Setup Figure 4-3 AMS Device Manager Using AMS Device Manager to configure the meter...
  • Page 97: Figure 4-4 Ams Device Manager - Overview

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 Figure 4-4 AMS Device Manager - Overview Using AMS Device Manager to configure the meter...
  • Page 98: Figure 4-5 Ams Device Manager - Guided Setup

    Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H AMS Device Manager - Guided Setup The Guided setup wizard provides configuration parameter settings for the meter. The Guided Setup is a subset of the Manual Setup parameters.
  • Page 99 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 After all of the data shown below is entered, click Apply to write the parameters to the meter. Click the tab to configure Frequency/Digital Output 1, Frequency/Digital Outputs 2 and 3 Source and drive Mode.
  • Page 100: Figure 4-6 Ams Device Manager - Service Tools All Variables Status Indicators

    Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Click the tab to view a graphical display of the Primary, Secondary, All Variables Third and Fourth Variables. Figure 4-6 AMS Device Manager - Service Tools All Variables status indicators Click to return to the Overview page.
  • Page 101: Figure 4-7 Display Meter K-Factors

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 Figure 4-7 Display Meter K-Factors Click to return to the Device Manager Overview page. Next Using AMS Device Manager to configure the meter...
  • Page 102: Figure 4-8 Ams Device Manager - Configure Manual Setup

    Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H AMS Device Manager - Manual Setup Use the wizard to configure the meter’s parameters. See Figure 4-3 Figure 4-4 Manual Setup and from the AMS Device Manager Configure menu click...
  • Page 103 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 Action parameters. Click , after you enter the data to write the parameters to the Apply meter. Click the Outputs tab. Follow the configuration instructions in the...
  • Page 104: Figure 4-9 Gating Configuration Parameter Edge Gated, Active High

    Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Calibration Gating configuration parameter selections are: – Edge gated, active high Figure 4-9 Gating configuration parameter Edge gated, active high High Calibration Start Calibration Stop –...
  • Page 105: Figure 4-12 Gating Configuration Parameter State Gated, Active Low

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 – State gated, active low Figure 4-12 Gating configuration parameter State gated, active low High Calibration Start Calibration Stop Click the tab (from the main Configuration page).
  • Page 106 Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Click the tab to select Configure Reverse Flow Detection, if desired. The Flow Analysis default setting is . Click the button to send the feature command to...
  • Page 107: Figure 4-14 Ams Device Manager - Service Tools Alerts

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 Click the tab to access the device alerts, variables, trends and maintenance Service Tools statuses or to edit the configuration parameters. Click the tab. If an alert condition exists, the alert type and Service Tools|Alerts description displays.
  • Page 108: Figure 4-15 Configuration Changes Dialog

    Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Figure 4-15 Configuration changes dialog Click the tab. The Variables page displays tabs for the Service Tools|Variables device’s Flow Data, Path Information, Flow Totals, and All Variables).
  • Page 109: Figure 4-17 Ams Device Manager - Service Tools All Variables

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 Click tab to view Primary, Secondary, Third Service Tools|Variables|All Variables and Fourth Variable parameter status. Figure 4-17 AMS Device Manager - Service Tools All Variables Gauges display each variable’s status as good or bad.
  • Page 110: Figure 4-18 Ams Device Manager - Service Tools Trends

    Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Click the tab to display the device variables (uncorrected Service Tools|Trends volume flow rate, pressure and temperature) trends. Figure 4-18 AMS Device Manager - Service Tools Trends Primary and Secondary variables display real-time uncorrected volume flow rate trends.
  • Page 111 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 and remains latched until acknowledged. Click (acknowledge) to clear the alarm. Using AMS Device Manager to configure the meter...
  • Page 112: Using A Field Communicator To Configure The Meter

    Follow all guidelines and precautions described in the Field Communicator User Manual and in the 3812 Liquid Ultrasonic Flow Meter documentation when working in a hazardous area. Installation Requirements • Emerson Field Communicator software, license, installation guide and user manual available on the Emerson Asset Optimization Field Communicator website: http://www2.emersonprocess.com/en-US/brands/Field-Communicator/Pages/Documenta- tion.aspx •...
  • Page 113: Figure 4-19 3812 Transmitter Field Wiring Conduit Entries

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 Procedure Remove electrical power to the meter. If installed, remove the endcap security latches and seals and then, remove the endcap. Refer to the Field Communicator Users Manual wiring diagrams and commissioning instructions provided with your handheld device.
  • Page 114: Figure 4-20 Field Communicator Wiring Diagram For The 3810 Series Electronics

    Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Wire Analog Input 1 (AI1) and Analog Output 1 (AO1) as shown in Figure 4-20 Appendix A, drawing DMC-004936. Figure 4-20 Field Communicator wiring diagram for the 3810 Series electronics Use the leads provided with the Field Communicator to connect to your device.
  • Page 115: Security Seals For The Meter

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 4: Configuration 3-9000-765 Rev H June 2017 Security seals for the meter For the integrity of the meter metrology and to prevent tampering with the transmitter electronics and transducer assemblies, attach security latches to the Shroud covering the...
  • Page 116 Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Security seals for the meter...
  • Page 117: Appendix A: Engineering Drawings

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Engineering drawings 3-9000-765 Rev H June 2017 Appendix A: Engineering drawings Appendix A Daniel 3812 Liquid Ultrasonic Flow Meter drawings List of Engineering Drawings This appendix contains the following engineering drawing(s) for the ultrasonic meter:...
  • Page 118 Engineering drawings Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Daniel 3812 Liquid Ultrasonic Flow Meter drawings...
  • Page 122: Appendix B: Open Source Licenses

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev H June 2017 Appendix B: Open source licenses Source code for executable files or libraries included in this product is provided per the indicated license in the table below. Hyperlinks to the controlling organization's websites are included in Section B.1...
  • Page 123: Gnu General Public License

    Open source licenses Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H Package File specification License Summary strace-4.5.14-1 strace trace system calls associated with a running pro sysconfig-1.2-1 sysconfig System configuration package sysfsutils-2.1.0-1 sysfsutils GPL/LGPL sysfs utilities tcpdump-3.8.3-1...
  • Page 124 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev H June 2017 The GNU General Public License (GPL) Version 2, June 1991 Copyright (C) 1989, 1991 Free Software Foundation, Inc. 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA Everyone is permitted to copy and distribute verbatim copies of this license document, but changing it is not allowed.
  • Page 125 Open source licenses Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H For example, if you distribute copies of such a program, whether gratis or for a fee, you must give the recipients all the rights that you have. You must make sure that they, too, receive or can get the source code.
  • Page 126 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev H June 2017 TERMS AND CONDITIONS FOR COPYING, DISTRIBUTION AND MODIFICATION 0. This License applies to any program or other work which contains a notice placed by the copyright holder saying it may be distributed under the terms of this General Public License.
  • Page 127 Open source licenses Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H 2. You may modify your copy or copies of the Program or any portion of it, thus forming a work based on the Program, and copy and distribute such modifications or work under the terms of Section 1...
  • Page 128 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev H June 2017 In addition, mere aggregation of another work not based on the Program with the Program (or with a work based on the Program) on a volume of a storage or distribution medium does not bring the other work under the scope of this License.
  • Page 129 Open source licenses Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H If distribution of executable or object code is made by offering access to copy from a designated place, then offering equivalent access to copy the source code from the same place counts as distribution of the source code, even though third parties are not compelled to copy the source along with the object code.
  • Page 130 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev H June 2017 Program by all those who receive copies directly or indirectly through you, then the only way you could satisfy both it and this License would be to refrain entirely from distribution of the Program.
  • Page 131 Open source licenses Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H conditions either of that version or of any later version published by the Free Software Foundation. If the Program does not specify a version number of this License, you may choose any version ever published by the Free Software Foundation.
  • Page 132 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev H June 2017 How to Apply These Terms to Your New Programs If you develop a new program, and you want it to be of the greatest possible use to the public, the best way to achieve this is to make it free software which everyone can redistribute and change under these terms.
  • Page 133 Open source licenses Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H The hypothetical commands `show w' and `show c' should show the appropriate parts of the General Public License. Of course, the commands you use may be called something other than `show w' and `show c';...
  • Page 134: Gnu Lesser General Public License

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev H June 2017 GNU Lesser General Public License GNU LESSER GENERAL PUBLIC LICENSE Version 3, 29 June 2007 Copyright © 2007 Free Software Foundation, Inc. <http://fsf.org/> Everyone is permitted to copy and distribute verbatim copies of this license document, but changing it is not allowed.
  • Page 135 Open source licenses Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H The "Corresponding Application Code" for a Combined Work means the object code and/or source code for the Application, including any data and utility programs needed for reproducing the Combined Work from the Application, but excluding the System Libraries of the Combined Work.
  • Page 136 Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev H June 2017 4. Combined Works. You may convey a Combined Work under terms of your choice that, taken together, effectively do not restrict modification of the portions of the Library contained in the Combined Work and...
  • Page 137 Open source licenses Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H 5. Combined Libraries. You may place library facilities that are a work based on the Library side by side in a single library together with other library facilities that are not Applications and are not covered by this...
  • Page 138: Bsd Open Source License

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev H June 2017 BSD Open Source License For more details about the Open Source BSD license or the Open Source Initiative, follow the link below: http://www.opensource.org/licenses/bsd-license.php Copyright (c) <YEAR>, <OWNER>...
  • Page 139: M.i.t License

    Open source licenses Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual June 2017 3-9000-765 Rev H M.I.T License For more details about the Open Source MIT license or the Open Source Initiative follow the link below: http://www.opensource.org/licenses/mit-license.php The MIT License Copyright (c) <year>...
  • Page 140: Appendix C Index

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Index 3-9000-765 Rev G December 2014 Appendix C Index I/O connections ..............57 Input/Output ................3 C.1 Manual Index Intrinsically Safe ................ 3 junction box junction box security seal ......67 Acronyms, abbreviations and definitions ......3...
  • Page 141 Index Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual December 2014 3-9000-765 Rev G incorrect sling attachment clamped band shroud ..........44 .............6 safety precautions using swivel hoist rings latched single band shroud ....36 ...........6 Split shroud security seals split shroud ........70...
  • Page 142 Middle East, Africa: Dubai, UAE Automation Solutions business unit. The Daniel name and logo are T +971.4.811.8100 trademarks of Daniel Industries, Inc. The Emerson logo is a Asia Pacific: Singapore trademark and service mark of Emerson Electric Co. All other T +65.6777.8211...

Table of Contents