4.20 Checking Front End Module Block input logic

4.20.1 Mode Logic by TP Command
Mode
EGSM Tx
DCS Tx
PCS Tx
EGSM Rx
DCS Rx
PCS Rx
WCDMA
Parameter
Input Logic Level
Copyright © 2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Antsw0
L
L
L
H
H
H
L
Table 4-1. Front End module(SKY77521) Mode Control Logic
Minimum
Low
High
Table 4-2. SKY77521 Logic Control Levels (TXEN, BS1, BS2)
Antsw1
Antsw2
L
H
H
H
H
H
L
H
H
H
H
L
H
L
Typical
-0.3
-
1.2
-
- 133 -
4. TROUBLE SHOOTING
Antsw3
L
L
L
X
X
X
H
Maximum
Units
0.55
V
Vbatt