Be sure to check if the sensitivity value is in 53 ~ 59.
If the value is out of the limites, check the following matters;
Batteries voltage
Setting of QV-200
Filter
7. Put the Color temperature filter LA-120 (Orange) on the ND filter ND-50 (Grey), and put the lens of the
QV-200 on the LA-120 , then enter " 0 " (Zero).
The following message will be appeared on the PC.
rglim_h = c4 rglim_l = 7d bglim_h = 169 bglim_l = f0
ryg = 69
byg = 6e
GOFS = 8
ADJ_ID : H'11ff
sum = H' 11037b4
Success!!
flashwrite OK.
Patch Write.
LUT Write.
finished!
8. Check the image of the QV-200 , then reload the image which saved in PC, if necessary.
— 10 —