6. Service points

Cautions when removing the Upper case
In the Upper case, an operation PWB is installed. When removing, lift carefully without using excessive force to
prevent damaging the ESW1 and ESW2 connector.
Cautions when removing the drive PWB
When removing the drive PWB, there is danger of damaging the connector connecting the fan PWB. Lift up the part
near the drive PWB connector and disconnect the connector before removing the drive PWB.
Before Replacing the LCD / Lens Prism
You should not replace separately the parts of the liquid crystal LCD / Lens Prism because it works properly only
when used together. Therefore, regarding these parts, you can either replace part , LCD / Lens Prism assembly, or
send the whole unit LCD / Lens Prism assembly back to HITACHI, where we will replace the malfunctioning part,
recondition the device and send it back to you.
DISTRIBUTOR
20
PWB assembly Drive
Do not disassemble the unit
because replacement of separate
parts is not possible.
Return
ESW2
CNSW
ESW1
Connector
HITACHI
Replacement of G Panel
G Panel
Reconditioning