GENERAL INFORMATION
The 5882AP RF receiver is designed for use with control
panels that support an RF receiver connection via the
remote keypad connection points. The receiver recognizes
alarm, status and keypad control messages from wireless
transmitters operating at 315 MHz.
One or two individually identified receivers can be
employed, depending on the control used. Connection of
multiple receivers to a control can provide redundant
coverage or extend coverage in large areas. Multiple
receivers do not increase the number of transmitters that the
system can support. See the control's instructions for specific
information regarding the number and type of receivers that
can be supported.
These receivers feature a Spatial Diversity System which
virtually eliminates the possibility of "Nulls" and "Dead
Spots" within the coverage area.
The 5882AP RF receiver is used in conjunction with 5800AP
series transmitters.
The number of zones that the 5882AP receiver can support
depends on the control with which it is used. See the control
panel's instructions for specific details.
If a receiver is connected to a system in which more than
the permitted number of wireless zones have been
programmed, a "SET UP ERROR" message (alpha keypads)
or an "E4" or "E8" message (fixed-word keypads) will be
displayed on the system's keypad, and none of the zones will
be protected.
The instruction manual that accompanies the control
includes
recommendations
transmitter locations, the types of wireless zones that can
be
programmed
(e.g.,
INTERIOR, etc.), and the procedure for programming the
receivers.
These receivers should not be installed in an area subject to
environmental extremes of below freezing (such as in a
refrigerated area) or extremely high temperatures (such as
an attic).
INSTALLATION
With some controls, a receiver may be mounted directly
inside the control's cabinet (receiver circuit board only,
without its plastic housing) instead of remotely (in its own
housing). In both cases, avoid mounting the receiver
antennas against a metal surface.
1.
Remove the receiver's cover by inserting and
twisting a screwdriver blade in the slot at the center of
the cover's lower edge.
2.
If the receiver is to be mounted within the control's
cabinet (refer to Figure 1):
a.
Remove the receiver's circuit board from its base by
bending back the two flexible plastic tabs that hold
the board's lower edge.
b.
In the control's cabinet, unfasten and move the
control
circuit
installed).
INSTALLATION AND SETUP GUIDE
regarding
receiver
ENTRY/EXIT,
PERIMETER,
board
downward
(if
c.
Hang two mounting clips (provided with the
receiver) on the raised cabinet tabs, as shown in
Detail B of Figure 1.
d.
Insert the top of the receiver board between the
rows of slots at the top of the cabinet, as shown in
Detail A.
e.
Position the base of the receiver board onto the
mounting clips, and secure it to the cabinet with
the supplied screws. See Detail B.
f.
Hang two mounting clips (supplied with the control
board), on the raised cabinet tabs as shown in
Detail C in Figure 1.
g.
Insert the top of the control board into the slots of
the mounting clips secured in step e above.
h.
Position the lower end of the control board into
place on the mounting clips and secure both to the
cabinet with the two supplied screws.
i.
Insert both grounding lugs (supplied with the
receiver) through the top of the cabinet into the left
hand terminals of the antenna blocks (located on
the upper edge of the receiver board), and secure
them to the cabinet with the screws provided, as
shown in Detail D.
j.
Insert the receiver's antennas through the top of
the cabinet, into the block's right-hand terminals,
and tighten the screws.
k.
Affix the receiver's Summary of Connections label
to the inside of the control's cabinet door.
l.
Discard the receiver's unused plastic cover and
and
base.
3.
If the receiver is to be located remotely from the
control in its own plastic enclosure (not in a cabinet):
You will not need the circuit board mounting clips,
grounding lugs, and screws included with the receiver.
a.
If concealed wiring is to be used, route it through
the rectangular opening at the rear of the base
before mounting. For surface wiring entry, a thin
breakaway area is provided along the base's right
edge.
b.
Mount the receiver in the selected location. For
greatest security, use all four mounting holes (two
key slot holes and two round holes) provided in the
plastic base.
c.
Affix the receiver's Summary of Connections label
to the inside of the housing cover.
4.
Setting the DIP switches
Set the receiver's DIP switch to identify the receiver's
address (refer to the DIP switch chart in Figure 2).
5.
Insert the wiring plug (with 4 flying leads) into
the mating socket on the receiver (see Figure 2 for
socket location). Connect the 4 wires to the control's
corresponding remote keypad connection points (see
already
"Interface Wiring" in the SPECIFICATIONS section).
N7635-1V2 12/07 Rev. A
ADEMCO 5882AP
RF RECEIVER

Advertisement

loading

Summary of Contents for Honeywell ADEMCO 5882AP

  • Page 1 N7635-1V2 12/07 Rev. A ADEMCO 5882AP RF RECEIVER INSTALLATION AND SETUP GUIDE GENERAL INFORMATION Hang two mounting clips (provided with the receiver) on the raised cabinet tabs, as shown in The 5882AP RF receiver is designed for use with control Detail B of Figure 1.
  • Page 2 Install the antennas in the right-hand terminals of Current: 60mA. the two terminal blocks at the upper edge of the circuit 0perating Temperature: 0°C – 50°ÁC board, one into each block’s right-hand terminal, and Interface Wiring: tighten the screws to secure them. RED 12VDC input (+) Aux Power If the receiver is mounted in a cabinet, insert the GREEN: Data Out to Control...
  • Page 3 USE MAX. OF 220 ft. (67m) OF #22 (0.64mm) ANTENNAS WIRE OR 550 ft. (168m) OF #18 (1mm) WIRE CIRCUIT INSERT IN FOR EACH RUN. 20 ft. MAX. IN COMMERCIAL BOARD RIGHT-HAND FIRE INSTALLATIONS. (SEE RECEIVER'S TERMINALS INSTRUCTIONS). TO CONTROL'S YELLOW NOTE: WHEN CIRCUIT BOARD IS MOUNTED IN KEYPAD TERMINALS.
  • Page 4 Seller shall have no obligation under this Limited Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other than Honeywell factory service. Connection of any device(s) to a communicating bus of a Honeywell security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell shall void this warranty.