Advertisement

Electric Storage Water Heater
Tronic 1000T
Installation and operating instructions
Please read the installation instructions before installing the appliance!
Please read the operating instructions before commissioning the appliance!
Please observe the safety instructions in the operating instructions!
The installation location must meet the manufacture's requirements!
Installation must only be carried out by an authorised person!
6720821421-00.1V

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Tronic 1000T

  • Page 1 6720821421-00.1V Electric Storage Water Heater Tronic 1000T Installation and operating instructions Please read the installation instructions before installing the appliance! Please read the operating instructions before commissioning the appliance! Please observe the safety instructions in the operating instructions! The installation location must meet the manufacture's requirements!
  • Page 2: Table Of Contents

    2 | Contents Contents 9.2.3 High electricity bills ....16 Key to symbols and safety instructions ..3 9.2.4 Continuous discharge from ECV &...
  • Page 3: Key To Symbols And Safety Instructions

    ▶ For service of this water heater phone the Bosch TT Service Department on AU 1300 30 70 37, or NZ 0800 543 352. Tronic 1000 T...
  • Page 4 4 | Key to symbols and safety instructions Notice to Victorian Customers from the Victorian Plumbing Hydrogen warnings Industry Commission WARNING: This water heater must be installed by a licensed person as If the hot water heater is not used for two required by the Victorian Building Act 1993.
  • Page 5: Standard Delivery

    Standard delivery | 5 For your safety: CAUTION: WARNING: The activation of the thermal cut-out It is normal that small quantities of water (up indicates a possibly dangerous situation. to 15 litres of water in a 24 hour period) are ▶...
  • Page 6: Appliance Details

    PTR safety valve. Bosch recommends that the anode be Water is stored within the steel inner tank and is heated to the inspected and replaced every five years or thermostat set temperature by the element.
  • Page 7 Appliance details | 7 New Zealand. However, in areas where Total Dissolved Solids (TDS) exceeds 2500mg/L, detrimental effects on water heater performance and longevity will result. Anode Should your water supply have a TDS of greater than 600mg/L, the installed anode must be aluminium (blue) or hydrogen gas can accumulate at the top of the water heater in long periods of no use.
  • Page 8: Technical Properties

    8 | Appliance details Technical properties Technical characteristics Unit EWS 080. EWS 125. EWS 160. EWS250. EWS 315. EWS 400. General characteristics Nominal Delivery Stored Capacity Element rating 1.8/2.4/ 1.8/2.4/ 1.8/2.4/3.6 3.6/4.8 3.6/4.8 3.6/4.8 Water supply data Water connections RP ¾" / 20mm Relief valve setting Expansion control valve (ECV) Maximum supply pressure with (ECV)
  • Page 9 Appliance details | 9 Technical characteristics Unit EWS 135. EWS 180. EWS260. General characteristics Nominal Capacity Element rating 2.0/3.0 2.0/3.0 3.0/4.0 Water supply data Water connections RP ¾" / 20mm Relief valve setting Expansion control valve (ECV) Maximum supply pressure with (ECV) Maximum supply pressure without (ECV) Electrical characteristics Power supply voltage...
  • Page 10: Dimensions

    10 | Appliance details Dimensions 3.4.1 Side Connections Fig. 3 Dimensions in mm (Vertical installation) Appliance EWS 80... 1060 EWS 125... 1511 1305 EWS 160... 1512 1295 EWS 250... 1407 1161 EWS 260... 1407 1161 EWS 315... 1710 1464 EWS 400... 1731 1464 Table 4...
  • Page 11: Top Connections

    Storing and transportation | 11 3.4.2 Top Connections Fig. 4 Dimensions in mm (Vertical installation) Appliance EWS 135... 1467 EWS 180... 1408 Table 5 Electrical wiring diagram DANGER: Do not reset the thermal cut-out until it has been serviced by an authorised person. WARNING: Do not operate this electric storage water heater without a thermostat and non...
  • Page 12: Installation Instructions

    12 | Installation instructions WARNING: CAUTION: Electric water heaters are heavy and bulky. The electric storage water heater should not Australian States and Territories have a be located in an area where leakage of the Principal Occupational Health and Safety tank or water connection will result in (OH&S) Act which contains requirements damage to the area adjacent to it or to lower...
  • Page 13: Pressure Limiting Valve (Not Supplied With The Appliance)

    Connections to this water heater must not be welded, brazed, or soldered Bosch recommends the installation of a temperature limiting connections. Connect only with device between the water heater and the hot water outlets compression or mechanical fittings supplying a sanitary outlet, in order to reduce the risk of scalding.
  • Page 14: Electrical Connection

    14 | Electrical connection NOTICE: Electrical connection This drain pipe must fall continuously, shall be left open to the atmosphere, and shall be Connection to this storage water heater must in a frost free environment be from a single phase 240V 50Hz supply and comply with AS/NZS 3000 Wiring Rules.
  • Page 15: Seismic Strapping

    Seismic strapping | 15 Seismic strapping New Zealand regulations require storage tanks to be fixed with seismic strapping as per NZS4603 or NZS4607. Fig. 6 [A] Extra centre strap for water heaters exceeding 200L [B] Storage water heaters to be restrained with 25x1 galvanized steel straps tensioned when fixed in place.
  • Page 16: Commissioning

    16 | Commissioning Commissioning Service Before commissioning DANGER: Electric shock! ▶ Isolate the appliance from the power NOTICE: Do not start the appliance without supply using the circuit breaker isolation water! switch or another protection device ▶ Only operate the appliance once it has before carrying out any work on been filled with potable water.
  • Page 17: Continuous Discharge From Ecv & Ptr Valves

    Service contact details trouble free operation. Bosch has an extensive network of service agents that may be contacted in event of failure of your water heater. 10.1 Periodic Inspection Please contact AU 1300 30 70 37, NZ 0800 543 352, or Email hotwater.warranty@au.bosch.com.
  • Page 18: Pressure And Temperature Relief Valve (Ptr Valve)

    18 | Maintenance and repair ▶ Disconnect the cold water connection to the appliance and DANGER: attach drain hose. Before manually operating the relief valve, ▶ Operate the lever on the PTR valve again allowing air into make certain no one will be exposed to the the water heater.
  • Page 19: Water Quality

    Water quality | 19 Water quality Water quality table All Bosch water heating appliances are constructed from high Maximum levels: quality materials and components, and all are certified for compliance with relevant parts of Australian and New Zealand Saturation Total Chlorides Sodium Iron gas, electrical and water standards.
  • Page 20 Warranty Robert Bosch (Australia) Pty Ltd Thermotechnology Division Bosch warrants, at its option, to repair or replace your water heater or relevant part thereof (Product) if such Products are Voluntary Repair or Replacement Warranty faulty or defective in manufacture or materials during the warranty period specified below.
  • Page 21: Warranty Details | 21

    Failure to service Product in accordance with recommendations in instruction manuals for Product may result in a warranty claim under this voluntary warranty being rejected by Bosch. Bosch alerts end users that instruction manuals for Product contain specific recommendations for servicing and safety checks to be carried out on Product.
  • Page 22 3169. Claims received by post will take longer to process and manipulation, loss, destruction, access by unauthorised we encourage you to call. Bosch may refer you to one of its persons or unauthorised disclosure. Bosch Warranty Authorised Service Dealers.
  • Page 23 | 23 Notes Tronic 1000 T 6 720 821 421 (2017/04)

Table of Contents