CHAPTER 3: ETHERNET INTERFACE
OBJECT
OBJECT
VARIATION
NO.
NO.
6
21
0
1
2
9
10
22
0
1
2
5
6
23
0
1
2
5
6
30
0
SR3 SERIES PROTECTIVE RELAY PLATFORM – COMMUNICATIONS GUIDE
DESCRIPTION
16-Bit Binary Counter
without Flag
Frozen Counter(Variation 0
is used to request
defaultvariation)
32-Bit Frozen Counter
16-Bit Frozen Counter
32-Bit Frozen Counter
without Flag
16-Bit Frozen Counter
without Flag
Counter Change Event
(Variation 0 is used to
request default variation)
32-Bit Counter Change
Event
16-Bit Counter Change
Event
32-Bit Counter Change
Event with Time
16-Bit Counter Change
Event with Time
Frozen Counter Event
(Variation 0 is used to
request default variation)
32-Bit Frozen Counter Event 1 (read)
16-Bit Frozen Counter Event 1 (read)
32-Bit Frozen Counter Event
with Time
16-Bit Frozen Counter Event
with Time
Analog Input (Variation 0 is
used to request default
variation)
REQUEST
FUNCTION
QUALIFIER CODES
CODES (DEC)
(HEX)
1 (read) 7 (freeze)
00, 01 (start-stop) 06
8 (freeze noack) 9
(no range, or all) 07,
(freeze clear) 10
08 (limited quantity)
(frz. cl. noack) 22
17, 28 (index)
(assign class)
1 (read) 22
00, 01 (start-stop) 06
(assign class)
(no range, or all) 07,
08 (limited quantity)
17, 28 (index)
1 (read) 22
00, 01 (start-stop) 06
(assign class)
(no range, or all) 07,
08 (limited quantity)
17, 28 (index)
1 (read) 22
00, 01 (start-stop) 06
(assign class)
(no range, or all) 07,
08 (limited quantity)
17, 28 (index)
1 (read) 22
00, 01 (start-stop) 06
(assign class)
(no range, or all) 07,
08 (limited quantity)
17, 28 (index)
1 (read) 22
00, 01 (start-stop) 06
(assign class)
(no range, or all) 07,
08 (limited quantity)
17, 28 (index)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
06 (no range, or all)
07, 08 (limited
quantity)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read) 22
00, 01 (start-stop) 06
(assign class)
(no range, or all) 07,
08 (limited quantity)
17, 28 (index)
DNP ETHERNET PROTOCOL SETTINGS
RESPONSE
FUNCTION
QUALIFIER CODES
CODES (DEC)
(HEX)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
---
---
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
---
---
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
---
---
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
---
---