Fisher 1061 Instruction Manual page 5

Pneumatic piston rotary actuator with style f & g mounting adaptations
Hide thumbs Also See for 1061:
Table of Contents

Advertisement

Instruction Manual
D100324X012
(1)
MOUNTING
ACTION
PDTC
Right‐Hand
PDTO
PDTC
Left‐Hand
PDTO
Left‐Hand
PDTC
(2)
(Optional)
PDTO
1. PDTC—Push‐down‐to‐close, and PDTO—Push‐down‐to‐open.
2. A left hand ball will be required for the NPS 3 through 12 Series B and the NPS 14 to 20, with or without attenuator.
Figure 2. Mounting Styles and Positions
LEFT‐HAND
MOUNTING
STYLE B
STYLE A
NOTES:
1
POSITION 1 IS STANDARD; POSITIONS 2 THROUGH 4 (SHOWN IN DOTTED LINES) ARE ALTERNATES.
2. BY Emerson Automation Solutions DEFINITION:
D
FORWARD FLOW IS INTO THE FACE SIDE OF DISK , OR BALL SEALING SURFACE.
D
REVERSE FLOW IS INTO THE HUB SIDE OF THE DISK OR BALL.
43A6506‐A
A1579‐5
VALVE SERIES OR DESIGN
BALL/PLUG
ROTATION TO
V250
CLOSE
CCW
A
CCW
B
CCW
NA
CCW
NA
CW
NA
CW
NA
STYLE D
STYLE C
RIGHT‐HAND
MOUNTING
STYLES
CV500
V150, V200 & V300
V500
A
A
B
B
D
D
C
C
C
NA
D
NA
STYLE A
POSITION 1
4
3
STYLE D
FLOW
4
1061 F & G Actuator
VALVE SERIES OR DESIGN
DISK/BALL
ROTATION TO
V250
CLOSE
CW
NA
CW
NA
CW
C
CW
D
NA
NA
NA
NA
STYLE B
POSITION 1
1
1
4
2
3
RIGHT‐HAND MOUNTING
1
POSITION 1
POSITION 1
1
2
4
3
LEFT‐HAND MOUNTING
June 2017
8510B, 8532,
8560
& 9500
B
A
C
D
NA
NA
FLOW
2
STYLE C
2
3
5

Hide quick links: