Power Supply; Power Supply Specifications; Recommended Power Cord - Sony PWS-110RX1 Installation Manual

Network rx station
Hide thumbs Also See for PWS-110RX1:
Table of Contents

Advertisement

1-4. Power Supply

1-4-1. Power Supply Specifications

A switching regulator is used in the power supply unit of
the unit.
n
Be sure to use the unit within the following power-supply
voltage range.
Power voltage:
100 to 240 VAC (nominal voltage)
Power frequency:
50 or 60 Hz
Power consumption: 235 W max. (including options)
Inrush current:
50 A at 100 VAC
n
The AC power supply requires capacity including inrush
current.
If the AC power capacity is insufficient, the circuit breaker
of the AC power supply on the supply side may trip or the
unit may malfunction.
1-4 (E)

1-4-2. Recommended Power Cord

This unit does not come with a power cord.
To get a power cord, please contact your local Sony Sales
Office/Service Center.
w
. Use the approved Power Cord (3-core mains lead)/Appli-
ance Connector/Plug with earthing-contacts that con-
forms to the safety regulations of each country if appli-
cable.
. Use the Power Cord (3-core mains lead)/Appliance
Connector/Plug conforming to the proper ratings (Volt-
age, Ampere).
If you have questions on the use of the above Power Cord/
Appliance Connector/Plug, please contact your local Sony
Sales Office/Service Center.
w
. Never use any damaged power cord.