Sound Data; Most Popular Matches; Txv Usage; Ahri Standard 210/240 - Lennox 14ACx–024-230A02 Manual

Merit series r-410a
Table of Contents

Advertisement

SOUND DATA

Unit
1
Model
018
024
030
036
041
042
047
048
059
060
NOTE - the octave sound power data does not include tonal correction.
Tested according to AHRI Standard 270-2008 test conditions.
1

MOST POPULAR MATCHES

Outdoor Unit
Model No.
14ACX(-)(S)018
14ACX(-)(S)024
14ACX(-)(S)030
14ACX(-)(S)036
14ACX-041
14ACX(-)(S)042
14ACX-047
14ACX-048
14ACX-059
14ACX-060

TXV USAGE

Use this table for C33, C35, CH23, CH33, CH35 and CR33
Field Installed TXV Match-Ups.
Outdoor Unit
Model No.
14ACX(-)(S)018
14ACX(-)(S)024
14ACX(-)(S)030
14ACX(-)(S)036
14ACX-041
14ACX(-)(S)042
14ACX-047
14ACX-048
14ACX-059
14ACX-060
CX34 and CX35 upflow coils and all Lennox air handlers are shipped with a
factory installed TXV. In most cases, no change out of the valve is needed.
If a change out is required it will be listed in the "TXV SUBSTITUTIONS" table.
The correct TXV must be ordered separately and field installed.
C33, C35 and CH33 and CH35 coils - Replace the factory installed orifice with
the expansion valve listed .
CR33 and CH23 coils - Use the expansion valve listed.
Octave Band Linear Sound Power Levels dB, re 10
Center Frequency - HZ
125
250
500
69.5
70.5
71.0
69.5
72.0
70.5
72.5
74.0
74.0
73.5
75.0
74.0
76.5
74.0
73.5
73.5
75.5
74.5
76.5
77.5
77.5
76.5
74.0
73.5
79.5
76.5
76.5
76.5
77.5
77.5
Indoor Unit
Model No
CX34-25
CX34-25
CX34-31
CX34-38
CX34-49
CX34-49
CX34-62C
CX34-62C
CX34-62C
CX34-62C
Thermal Expansion Valve
(TXV)
12J18
12J18
12J18
12J19
12J20
12J20
12J20
12J20
12J20
12J20
Watts
-12
1000
2000
4000
71.0
69.0
63.5
70.5
67.5
62.5
72.0
67.5
61.5
72.5
67.5
62.5
73.5
70.0
62.5
73.5
70.5
64.0
73.5
69.0
63.5
73.5
70.0
62.5
72.5
68.0
63.0
73.5
69.0
63.5

AHRI STANDARD 210/240

Cooling or heating capacities are net values, including
the effects of blower motor heat, and do not include
supplementary heat. Power input is the total power input
to the compressor(s) and fan(s), plus any controls and
other items required as part of the system for normal
operation.
Units which do not have an indoor air-circulating blower
furnished as part of the model, i.e., split system with
indoor coil only, is established by subtracting from the
total cooling capacity 1250 Btu/h per 1,000 cfm, and by
adding the same amount to the heating capacity. Total
power input for both heating and cooling is increased by
365 W per 1,000 cfm of indoor air circulated.
*TXV SUBSTITUTIONS
Use this table to determine if the factory installed TXV in
the indoor unit needs to be replaced.
Outdoor Unit
Indoor Coil
Model No.
14ACX(-)(S)030 CX34-42
14ACX(-)(S)030 CX34-43
14ACX(-)(S)030 CX35-48
14ACX(-)(S)036 CX34-31
* CX34 and CX35 coils - The factory installed expansion valve must be
replaced with the expansion valve listed (ordered separately).
If the combination is not listed above, the factory installed TXV is used.
14ACX - 1.5 to 5 Ton Air Conditioner / Page 9
Sound Rating
1
Number (dB)
8000
57.5
76
57.5
76
56.5
76
56.5
76
58.5
78
58.5
78
60.5
80
58.5
78
60.5
78
60.5
80
Factory
Replacement
TXV
TXV
12J20
12J18
12J20
12J18
12J20
12J18
12J18
12J19