TXV/ORIFICE USAGE

Use this table for C33, CH23, CH33, CH35 and CR33 Field
Installed TXV/Orifice Match-Ups.
Model No.
Refrigerant Metering
Orifice (RFC)
Order No.
97M74
EL16XC1-018
97M75
EL16XC1-024
EL16XC1-030
10W99
EL16XC1-036
11W02
EL16XC1-041
97M77
EL16XC1-042
97M78
EL16XC1-047
10W86
EL16XC1-048
11W07
EL16XC1-060
11W11
CX34 upflow coils and all Lennox air handlers are shipped with a factory
installed TXV. In most cases, no change out of the valve is needed.
If a change out is required it will be listed in the "TXV SUBSTITUTIONS" table.
The correct TXV must be ordered separately and field installed.
C33 and CH33 coils - Use the orifice shipped with the outdoor unit or replace
the factory installed orifice with the expansion valve listed.
CR33 and CH23 coils - Use the orifice shipped with the outdoor unit or use the
expansion valve listed.
CH35 coils - Factory installed orifice must be replaced with the expansion
valve listed.

MOST POPULAR MATCHES

Outdoor Unit
Model No.
EL16XC1-018
EL16XC1-024
EL16XC1-030
EL16XC1-036
EL16XC1-041
EL16XC1-042
EL16XC1-047
EL16XC1-048
EL16XC1-060

AHRI STANDARD 210/240

Cooling or heating capacities are net values, including
the effects of blower motor heat, and do not include
supplementary heat. Power input is the total power input
to the compressor(s) and fan(s), plus any controls and
other items required as part of the system for normal
operation.
EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 10
Thermal
Expansion
Valve (TXV)
Orifice Size
12J18
0.053
12J18
0.057
0.065
12J18
0.073
12J19
0.074
12J20
0.076
12J20
0.080
12J20
0.083
12J20
0.093
12J20
Indoor Unit
Model No
CX34-25
CX34-25
CX34-31
CX34-38
CX34-49
CX34-49
CX34-62C
CX34-62C
CX34-62C

*TXV SUBSTITUTIONS

Use this table to determine if the factory installed TXV in
the indoor unit needs to be replaced.
Indoor Coil or Air
Model
Handler
030
CX34-42
030
CX34-43
030
CX34/CX35-48
* CX34 coils and all air handlers - The factory installed expansion valve must
be replaced with the expansion valve listed (ordered separately).
If the combination is not listed above, the factory installed TXV is used.
Units which do not have an indoor air-circulating blower
furnished as part of the model, i.e., split system with
indoor coil only, is established by subtracting from the
total cooling capacity 1250 Btu/h per 1,000 cfm, and by
adding the same amount to the heating capacity. Total
power input for both heating and cooling is increased by
365 W per 1,000 cfm of indoor air circulated.
Factory
Replacement
TXV
TXV
21J20
21J18
21J20
21J18
21J20
21J18