Refrigerant r410a

Advertisement

Steps
6.Remove 4-way valve assy
Unscrew the fastening nut of the 4-way valve
assy coil and remove the coil. Wrap the 4
way Valve Assy with wet cotton and unsolder the
4 weld spots connecting the 4-way valve assy to
take it out.(Note: Refrigerant shouldbe
discharged firstly.) Welding process should
be as quickly as possible and keep wrapping
cotton wet all the time. Be sure not to burn out
the lead-out wire of compressor.
7.Remove motor and motor support
Remove the 4 tapping screws fixing the motor.
Pull out the lead-out wire and remove themotor.
Remove the 2 tapping screws fixingthe motor
support. Lift motor support to re-move it.
8.Remove the isolation sheet
Remove the screws fixing the isolation sheet
and then remove the isolation sheet.
Procedure
motor support
motor
4-way valve assy
isolation sheet