Repeater Cloning

You can transfer data stored in one VXR-1000 to another VXR-1000 by utilizing the handy
"Cloning" feature. This requires the optional T9101411 Cable and FRB-4 Alignment Interface
Box, so as to connect the Microphone jacks on the two repeaters as shown below.
To clone from one repeater to another, use the following procedure:
Ë
Turn both repeaters off, and connect the T9101411 Cable between the FRB-4 modular jack
and the "Source" repeater's Microphone jack. Turn the "Source" repeater On.
Ë
Connect the FRB-4 modular connector to the "Target" repeater's Microphone jack.
Ë
Turn the "Target" repeater On, and set the FRB-4's PTT switch to On. The "Source" re-
peater will now send its frequency data to the "Target" repeater.
Ë
Wait two seconds, then turn the "Target" repeater off. Now turn the "Source" repeater off.
Ë
Remove the T9101411 Cable and the FRB-4. All frequency data for the two repeaters are
now identical. They both may be turned on now for normal operation.
"Target" Repeater
32
FRB-4
www.radio-vertex.com.br | acent@radio-vertex.com.br
"Source" Repeater
Optional Cable
(T9101411)