Applications
The instrument can be used in many processes and
industries:
• Quality and quantity monitoring in the water/
wastewater industry
• Monitoring of processes in power stations
• Food and dairy industry processes
• Displaying and recording critical parameters in
production cycles
• Tank and level monitoring
• Temperature monitoring in metal working
• Cold storage and transportation monitoring
4 1 â
Your benefits
• Informative: interim, daily, monthly and yearly
analysis; counters, operation time and quantities;
min-, max- and average value recording
• Versatile: up to 6 universal inputs record all measuring
signals
• Clear layout: multi-coloured display, digital, bargraph
and curve display
• Compact: low installation depth, saves space and
money
TI115R/09/en
No. 51009568
• Safe: reliable data archiving with internal memory and
separate CompactFlash card (mechanically locked).
No data loss even in event of power failure!
• System-enabled: network integration and remote data
transmission via Ethernet, RS232/RS485 (modem)
and USB
• Available worldwide: integrated Web server function
for remote monitoring e.g. with E+H Fieldgate
®
Viewer
• Reliable: inputs are galvanically isolated from the
system
®
• Complete: ReadWin
2000 PC software package
contained in scope of supply for professional, tamper-
proof data processing
• Flexible: direct access to archived data also with MS
®
Excel or in ReadWin
2000 for example
®

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Ecograph T

  • Page 1: Technical Information

    Technical Information Ecograph T Multi Channel Recorder RSG30 Display, record, communicate Applications • Safe: reliable data archiving with internal memory and separate CompactFlash card (mechanically locked). The instrument can be used in many processes and No data loss even in event of power failure! industries: •...
  • Page 2: Function And System Design

    Ecograph T Function and system design Measuring principle Electronic acquisition, display, recording, analysis, remote transmission and archiving of analog and digital input signals. Measuring system Multi-channel data recording system with multi-coloured LCD display (120 mm / 4.7" screen size), galvanically isolated universal inputs (U, I, TC, RTD), digital input, transmitter power supply, limit relay, communication interfaces (USB, Ethernet, RS232/485), internal Flash memory and CompactFlash card.
  • Page 3: Measuring Range

    Ecograph T Measured Measuring range Maximum measured error Input variable of measuring range (oMR) impedance Current 0...20 mA ± 0.10 % Load: = 50 Ohm 0...5 mA 4...20 mA Overrange: up to 22 mA ( 980 kOhm Voltage > 1 V 0...10 V...
  • Page 4 Ecograph T Measured Limit values (steady-state, Cable open circuit detection/line influence/temperature variable without destroying input) compensation Measuring current: ≤ 1 mA Resistance Disengageable cable open circuit detection thermometer (RTD) Maximum barrier resistance (or line resistance): Max. 200 Ohm (4-wire) Max. 40 Ohm (3-wire) Maximum influence of barrier resistance (or line resistance) for Pt100, Pt500 and Pt1000: 4-wire: ±0.0002%/Ohm, 3-wire: ±0.002%/Ohm...
  • Page 5 Ecograph T Selectable functions Control input, ON/OFF message, pulse counter (13-digit, 64 bit), operating time, message+operating time. Functions of the control input: start recording, rear illumination OFF, setup lock, time synchronization. Output Auxiliary voltage output The auxiliary voltage is provided to activate the digital input (or sensors) with floating contacts and is galvanically isolated from the system and the inputs (testing voltage 500 V).
  • Page 6: Power Supply / Terminal Diagram

    Ecograph T Power supply / terminal diagram Electrical connection (wiring diagram) Cable RS 485 resistance RxD/TxD(-) RxD/TxD(+) Further units >20 ms Digital in (DI) 12 V - 24 VDC >5 mA 12 V - 24 VDC 10 k Power RS 232...
  • Page 7: Performance Characteristics

    Ecograph T Supply voltage Low voltage power supply: 115 / 230 V Extra-low voltage power supply: 24 V AC/DC Frequency Nominal frequency: 50 / 60 Hz Cable specification Screw or spring terminal blocks with reverse polarity protection: Digital I/O wire cross-section, RS485 and analog inputs: max. 1.5 mm (14 AWG) (spring terminals) Power wire cross-section: max.
  • Page 8: Installation Conditions

    Ecograph T Installation conditions Orientation Position of use as per DIN 16 257, NL 90 ± 30° Installation instructions Panel cutout and installation / design, dimensions: 144 mm 5.67” 86.5 mm 3.4” 137.9 mm 5.43” • Installation depth: approx. 171 mm (6.73 inch) (incl. terminals and fastening clips) +0.04...
  • Page 9: Mechanical Construction

    Ecograph T Degree of protection Front-panel IP 54 (IEC 60529, Cat. 2) NEMA 2 rear-panel IP 20 (IEC 60529, Cat. 2) Electrical safety IEC 61010-1, protection class I Low voltage: overvoltage category II Environment < 3000 m (< 9843 ft) above MSL (mean sea level)
  • Page 10 Ecograph T Resolution: 76,800 pixels (320 x 240 pixels) Rear illumination: 50,000 h half value time (= half brightness) Number of colors: 64 colors Point of view: Maximum point of view range: From the display center 50° to the left and right, 20° upward, 30° downward.
  • Page 11 Ecograph T • A green LED beside the CF slot indicates data access. During this process, the CF card must not be removed. Risk of losing data! Typical recording lengths: Requirements for the following tables: • No alarm point violation/event storage •...
  • Page 12: Certificates And Approvals

    Ecograph T Certificates and approvals CE mark The measuring system meets the legal requirements of the EC directives. The manufacturer confirms successful testing of the device by affixing the CE mark. UL listed for Canada and USA The device was examined by Underwriters Laboratories Inc. (UL) in accordance with the standards UL 61010- 1 and CSA C22.2 No.
  • Page 13 Ecograph T Accessories Scope of delivery • Unit (with terminals, as per your order) • 4 fastening clips • USB cable • Optional CompactFlash CF card (CF card is enclosed separately.) • PC operating and configuration software on CD-ROM • Delivery note •...
  • Page 14 Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel. +41 61 715 81 00 Fax +41 61 715 25 00 www.endress.com info@ii.endress.com TI115R/09/en/10.07 51009568 FM+SGML 6.0 ProMoDo...

Table of Contents