MODEL : AOU24RML
PROCESS
Assemble PWB ASSY
(FILTER PCB)
REGULATION
As shown in Fig.1, assemble PWB ASSY to INVERTER BOX A.
As shown in Fig.2, pull out the wires of PWB ASSY.
Don't sandwich ARRESTER (SA100) between PWB and INVERTER BOX A.
Don't sandwich ARRESTER
between PWB and
INVERTER BOX A.
R E P L A C E ME N T P A RT S
1
INVERTER BOX A
Pull out the wires of PWB ASSY
this way.
Fig.2
03-16
USED
1
INVERTER BOX A
PARTS
2
FILTER PCB
SCREW,TAPPING
3
FILTER PCB
2
Hook
Fig.1
3