MODEL : AOU24RML
PROCESS
Fix the wires to INVERTER BOX A
(HEATSINK THERMISTOR, etc)
REGULATIONS
As shown in Fig.1,fix the wires to INVERTER BOX A.
HEATSINK
THERMISTOR
R E P L A C E ME N T P A RT S
.
+ -
120
10mm
+ -
210 10mm
CN407(MAIN PCB)
WIRE WITH CONNECTOR
03-28
Fig.2
Hook
Pull out the wire
through this opening.
INVERTER BOX A
Fig.1