HP StoreFabric CN1100R User Manual

HP StoreFabric CN1100R User Manual

Dual port converged network adapter

Advertisement

Quick Links

HPE StoreFabric CN1100R Dual Port
Converged Network Adapter

User Guide

Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise
assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy
levels.
Part Number: 728508-002R
November 2015
Edition: 3

Advertisement

Table of Contents
loading

Summary of Contents for HP StoreFabric CN1100R

  • Page 1: User Guide

    HPE StoreFabric CN1100R Dual Port Converged Network Adapter User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
  • Page 2 © Copyright 2013, 2015 Hewlett Packard Enterprise Development LP The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.
  • Page 3: Table Of Contents

    Contents Technician notes ............................ 4 Warnings, cautions, and notes ..........................4 Introduction ............................5 Overview .................................. 5 Downloading files ..............................5 Installation prerequisites ............................5 Recording reference numbers ..........................5 LED indicators ................................6 Installing an adapter ..........................7 Installing a CNA in a server ............................7 Installing a low profile bracket for a CNA .........................
  • Page 4: Technician Notes

    Before installing the unit, review and adhere to all device-specific warnings provided in the HPE StoreFabric CN1100R Dual Port Converged Network Adapter User Guide and in Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products on the Hewlett Packard Enterprise website (http://www.hpe.com/support/Safety-Compliance-EnterpriseProducts).
  • Page 5: Introduction

    Introduction Overview The StoreFabric CN1100R 2P CNA is a dual-port converged network adapter that supports Gen8 ML and DL ProLiant servers and uses the Broadcom 57810s Meru-D. For more information about the StoreFabric CN1100R 2P CNA, see the Hewlett Packard Enterprise website (http://www.hpe.com/info/cna).
  • Page 6: Led Indicators

    LED indicators The CN1100R Adapter has two ports with LED indicators for activity and link for each port. A standard-height bracket is shown below with SFP+ ports and LED indicators. The CN1100R Adapter LED indicators operate as described in the following table. Item LED indicator Status...
  • Page 7: Installing An Adapter

    Installing an adapter Installing a CNA in a server WARNING: Disconnect the host from the power source before installing the CNA. Power down the server, and then remove the power cord. Remove the server case. Remove the blank panel from an empty x8 or larger PCIe bus slot. Identify the PCI Express option slot in which the CNA is to be installed.
  • Page 8 To install a low profile bracket: To remove any SFP transceivers or cables from the CNA transceiver cage assembly, pull the bail (handle) out and down to release the latch. Gently pull the SFP transceiver out. Store the transceiver in an ESD-safe place. Using a correctly sized slotted screwdriver, carefully remove the two board lock screws located at the top and bottom of the connector.
  • Page 9: Attaching Media

    Remove the standard profile bracket, and then store it for future use. Align the new mounting bracket tabs with the holes in the CNA. IMPORTANT: Do not push the bracket past the grounding tabs on the transceiver housing. Be sure the LEDs are properly aligned with the holes in the bracket. Install the screws that attach the CNA to the bracket.
  • Page 10: Connecting The Copper Cable

    For more information, see "Cable specifications (on page 14)". Connecting the copper cable Insert the transceiver into the cage. Be sure that the tab on the plug clicks into position. Connect one end of the copper cable to the CNA. Connect the other end of the cable to the converged network switch.
  • Page 11 Watch the server console for any POST error messages and the CNA for the correct BIOS startup message. Installing an adapter 11...
  • Page 12: Installing The Device Drivers

    For Linux, see the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays Reference Guide on the SPOCK website (http://www.hpe.com/storage/spock). An HP Passport is required for access. Installing BACS For more information about BACS, see the Broadcom BACS for FlexFabric and StoreFabric Adapters User Guide (http://www.hpe.com/support/HPE_BACS_UG_en) and the documentation available with the...
  • Page 13: Specifications

    Non-operating: 5 to 95% relative humidity, non-condensing 200 If/min (minimum) Airflow General specifications Specification Value StoreFabric CN1100R Dual Port Converged Network Adapter (QW990A) Controller 5.2 x 2.7 inches (13.208 cm x 6.89 cm) without bracket Dimensions (LxW) 4 Watts typical, 9 Watts maximum Power requirements...
  • Page 14: Cable Specifications

    Copper cables and SFP+ Ethernet optical modules (SR) Part number 455883-B21 10Gb SR SFP+ Optical cables * Part number PremierFlex OM3+ type cables BK837A 0.5 m PremierFlex LC/LC multi-mode optical cable BK838A 1 m PremierFlex LC/LC multi-mode optical cable BK839A 2 m PremierFlex LC/LC multi-mode optical cable BK840A 5 m PremierFlex LC/LC multi-mode optical cable...
  • Page 15: Hewlett Packard Enterprise Product Quickspecs

    Compliance Standard x8 PCI Express V2.0 (5 GT/s) support Other RoHS 6 of 6 IPv4, IPv6 Microsoft Windows Hardware Quality Labs Server Design Guide version 3.0 SNMP IPv4, TCP and UDP Checksum Offload IPv4/IPv6 TCP, Large Send Offload Receive-Side Scaling Jumbo Frames up to 9000 Bytes Hewlett Packard Enterprise product QuickSpecs For more information about product features, specifications, options, configurations, and compatibility,...
  • Page 16: Electrostatic Discharge

    Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices.
  • Page 17: Warranty And Regulatory Information

    Warranty and regulatory information Warranty information HPE ProLiant and x86 Servers and Options (http://www.hpe.com/support/ProLiantServers-Warranties) HPE Enterprise Servers (http://www.hpe.com/support/EnterpriseServers-Warranties) HPE Storage Products (http://www.hpe.com/support/Storage-Warranties) HPE Networking Products (http://www.hpe.com/support/Networking-Warranties) Regulatory information Safety and regulatory compliance For important safety, environmental, and regulatory information, see Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products, available at the Hewlett Packard Enterprise website (http://www.hpe.com/support/Safety-Compliance-EnterpriseProducts).
  • Page 18: Turkey Rohs Material Content Declaration

    • Russia: • Belarus: • Kazakhstan: Manufacturing date: The manufacturing date is defined by the serial number. CCSYWWZZZZ (serial number format for this product) Valid date formats include: • YWW, where Y indicates the year counting from within each new decade, with 2000 as the starting point;...
  • Page 19: Support And Other Resources

    Hewlett Packard Enterprise Support Center More Information on Access to Support Materials page (http://www.hpe.com/support/AccessToSupportMaterials). IMPORTANT: Access to some updates might require product entitlement when accessed through the Hewlett Packard Enterprise Support Center. You must have an HP Passport set up with relevant entitlements. Websites •...
  • Page 20: Customer Self Repair

    Software Depot (http://www.hpe.com/support/softwaredepot) • Customer Self Repair (http://www.hpe.com/support/selfrepair) • Insight Remote Support (http://www.hpe.com/info/insightremotesupport/docs) • Serviceguard Solutions for HP-UX (http://www.hpe.com/info/hpux-serviceguard-docs) • Single Point of Connectivity Knowledge (SPOCK) Storage compatibility matrix (http://www.hpe.com/storage/spock) • Storage white papers and analyst reports (http://www.hpe.com/storage/whitepapers) Customer Self Repair Hewlett Packard Enterprise products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement.
  • Page 21 • Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à Hewlett Packard Enterprise de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés. • Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également conçues pour permettre au client d'effectuer lui-même la réparation.
  • Page 22 spedizione fornito. La mancata restituzione del componente può comportare la fatturazione del ricambio da parte di Hewlett Packard Enterprise. Nel caso di riparazione da parte del cliente, Hewlett Packard Enterprise sostiene tutte le spese di spedizione e resa e sceglie il corriere/vettore da utilizzare. Per ulteriori informazioni sul programma CSR di Hewlett Packard Enterprise, contattare il centro di assistenza di zona.
  • Page 23 • Obligatorio—componentes cuya reparación por parte del usuario es obligatoria. Si solicita a Hewlett Packard Enterprise que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio. •...
  • Page 24 Hewlett Packard Enterprise vermeldt in de documentatie bij het vervangende CSR-onderdeel of het defecte onderdeel aan Hewlett Packard Enterprise moet worden geretourneerd. Als het defecte onderdeel aan Hewlett Packard Enterprise moet worden teruggezonden, moet u het defecte onderdeel binnen een bepaalde periode, gewoonlijk vijf (5) werkdagen, retourneren aan Hewlett Packard Enterprise. Het defecte onderdeel moet met de bijbehorende documentatie worden geretourneerd in het meegeleverde verpakkingsmateriaal.
  • Page 25 Support and other resources 25...
  • Page 26 Support and other resources 26...
  • Page 27 Support and other resources 27...
  • Page 28: Remote Support

    Remote support Remote support is available with supported devices as part of your warranty or contractual support agreement. It provides intelligent event diagnosis, and automatic, secure submission of hardware event notifications to Hewlett Packard Enterprise, which will initiate a fast and accurate resolution based on your product’s service level.
  • Page 29: Acronyms And Abbreviations

    Acronyms and abbreviations BACS Broadcom Advanced Control Suite Comprehensive Configuration Management Conformité Européenne (European Conformity) converged network Converged Network Adaptor Canadian Standards Association Distributed State Machine electrostatic discharge Fibre Channel Forwarder FCoE Fibre Channel over Ethernet IPv4 Internet Protocol version 4 IPv6 Internet Protocol version 6 iSCSI...
  • Page 30 Lucent connector Media Access Control MPIO multipath I/O PCI Express Peripheral Component Interconnect Express PCIe Peripheral Component Interconnect Express PCI-X peripheral component interconnect extended physical layer device POST Power-On Self Test RoHS Restriction of Hazardous Substances Red Hat Package Manager small form-factor pluggable SFP+ enhanced small form-factor pluggable...
  • Page 31 World Wide Name Acronyms and abbreviations 31...
  • Page 32: Documentation Feedback

    Documentation feedback Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:docsfeedback@hpe.com). When submitting your feedback, include the document title, part number, edition, and publication date located on the front cover of the document. For online help content, include the product name, product version, help edition, and publication date located on the legal notices page.

Table of Contents