Adjustment
1. Remove the face plate.
2. Turn the pulley by hand, and insert the tip of the needle into the needle hole.
3. Loosen the lock nut.
4. Adjust the needle tip to the front/back center position of the needle hole using the socket set screw (CP, M4 x 12).
5. Tighten the lock nut.
Socket set screw (CP, M4 x 12)
Rear of main unit
Forward and back adjustment of needle and presser
Lock nut
Needle hole
Needle tip
position