D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause (default 1 s)
; : Dial Pause (default 3 s)
X: Extension Dialing
0–9,
, #: Dial Code
Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
PBX Environment—Alternate Extension Transfer Sequence (Up to 16 digits /
[0-9 * # D R F T X , ;])
Specifies the sequence for transferring calls to extensions in the Alternate Extension Group.
Default
FX
Value Range
Max. 16 digits consisting of 0–9,
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause (default 1 s)
; : Dial Pause (default 3 s)
X: Extension Dialing
0–9,
, #: Dial Code
Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
Feature Manual References
20.1.3 Unified Messaging—Alternate Extension Group
Dialing Parameters/MSW Notification
Dialing Parameters—Call Transfer No Answer Time (10-60 s)
Specifies the length of time that the system waits before retrieving the transferred call when there is no answer
at the destination extension.
Note
Make sure that the duration of Call Transfer No Answer Time is longer than the duration of Call Forwarding
No Answer Time at the PBX. Otherwise, the PBX may forward the call immediately to the extension's
Intercept Routing destination according to PBX programming, rather than return the call to the system.