8
Mounting the spool holder
.01.06
Fig. 8 - 06
8
Connecting the plug-in connections and earth cables
.02
Fig. 8 - 07
● Connect all plug connections as described in the operations manual of the drive
● The following ground cables must be attached in order to discharge static electricity.
● Attach ground cables for machine, main switch, control unit and motor to ground point 1.
Installation and commissioning
● Mount the spool holder as shown in
Fig. 8-08.
● Insert the spool holder into the hole in
the table top and fasten it with the nuts
enclosed.
1
21