Table 5. Unit Indoor Matchups for Subcooling (XP14-XXX-230-01 through 07)
Target
Subcooling
INDOOR MATCHUPS
Heating Cooling
(+5ºF)   (+1ºF)
XP14−018
CBX27UH-018/024
13
CBX32MV-018/024
15
CBX40UHV-024
15
XP14−024
CBX26UH-024
25
CBX27UH-018/024
15
CBX32M-018/024
16
CBX32M-030
15
CBX32MV-018/024
16
CBX32MV-024/030
15
CBX40UHV-024
16
CBX40UHV-030
15
CH23-41
16
CH33-25A
16
CH33-42B
14
CH33-36A
16
CH33-36C
16
CR33-30/36A/B/C
25
CX34-25A/B
16
CX34-31A/B
15
CX34-36A/B/C
16
CX34-38A/B
S/N# 6007
11
and after
CX34-38A/B
before S/N#
14
6007
XP14−030
CH23-41
11
CH23-51
6
CBX26UH-024
30
CBX26UH-030
29
CBX27UH-030
11
CBX32M-030
11
CBX32M-036
11
CBX32MV-024/030
11
CBX32MV-036
15
CBX40UHV-024, -030
11
CBX40UHV-036
15
C33-44C
11
CH33-36C
11
*Add
INDOOR MATCHUPS
charge
XP14−030 (Continued)
lb
oz
7
0
8
CH33-42B
7
0
0
CR33-30/36A/B/C
7
0
0
CX34-31A/B
CX34-38A/B
S/N# 6007
lb
oz
and after
CX34-38A/B
Before S/N#
7
0
0
6007
8
1
2
CX34-43B/C
XP14−036
8
0
14
8
1
3
C33-44C
8
0
14
CBX26UH-036
8
1
2
CBX26UH-037
8
0
14
CBX27UH-036
8
1
2
CBX32M-036
8
0
2
CBX32M-042
6
0
7
CBX32MV-036
11
1
10
CBX32MV-048
8
1
0
CBX40UHV-036
8
0
4
CBX40UHV-042, -048
7
0
2
CH33-50/60C
8
0
14
CH33-44B
8
1
3
CH33-48B
8
1
8
CR33-50/60C
11
2
2
CR33-48B/C
11
2
2
CX34-49C
lb
oz
CX34-43B/C, -50/60C
CX34-38A/B
S/N# 6007
6
0
8
and after
CX34-38A/B
before S/N#
6
1
12
6007
XP14−042
8
0
6
8
2
3
CH23-68
6
2
4
CBX26UH-042
6
1
6
CBX27UH-042
6
2
4
CBX32M-048
6
1
6
CBX32MV-048
7
3
0
CBX40UHV-042, -048
6
1
6
CH33-43
7
3
0
CH33-62D
6
2
3
CH33-50/60C
3
0
0
CH33-60D
Target
*Add
Subcooling
charge
Heating Cooling
(+5ºF)   (+1ºF)
lb
oz
6
6
1
12
30
8
0
8
11
6
1
6
6
6
2
3
11
6
2
3
15
11
2
14
lb
oz
13
6
0
0
26
5
0
0
25
4
1
9
13
6
0
3
13
6
0
2
13
6
0
3
13
6
0
3
11
8
2
5
13
6
0
3
11
8
2
5
11
8
2
5
13
6
1
7
13
6
1
8
25
4
1
15
25
5
0
9
13
6
2
4
13
6
1
8
6
6
0
0
13
6
0
0
lb
oz
20
9
0
13
27
6
0
0
12
6
0
8
12
6
0
7
12
6
0
8
12
6
0
8
12
6
0
7
12
6
0
10
12
6
0
7
12
6
0
4
Page 30
Target
Subcooling
INDOOR MATCHUPS
Heating Cooling
(+5ºF)   (+1ºF)
XP14−042 (Continued)
CR33-50/60C,-60D
26
CX34-62C, -62D
12
CX34-49C
12
CX34-60D
12
XP14−048
CBX26UH-048
8
CBX27UH-048
11
CBX32M-048, -060
11
CBX32MV-048
25
CBX32MV-060
11
CBX40UHV-048
25
CBX40UHV-060
11
CBX32MV-068
10
CH23-68
20
CH33-50/60C
11
CH33-62D
10
CH33-60D
11
CR33-50/60C
35
CR33-60D
37
CX34-62C, -62D
10
CX34-49D
11
CX34-60D
11
XP14−060
CBX26UH-048
12
CBX26UH-060
14
CBX27UH-060
12
CBX32M-048, -060
12
CBX32MV-048, -060
12
CBX40UHV-048, -060
12
CBX32MV-068
12
CH23-68
12
CH33-50/60C
12
CH33-62D
12
CX34-62C, -62D
12
*Add charge = Extra matchup amount required in addi­
tion to charge indicated on Heat Pump nameplate (re­
member to also add any charge required for line set
differences from 15 feet). SN indicates serial number.
*Add
charge
lb
oz
6
0
4
6
0
9
6
0
7
6
0
4
lb
oz
7
1
9
8
1
2
8
1
2
8
0
0
8
1
2
8
0
0
8
1
2
7
1
12
9
2
9
8
1
1
7
1
14
8
0
0
5
0
0
6
0
0
7
1
7
8
0
14
8
0
0
lb
oz
7
1
0
4
0
0
5
0
0
5
0
0
5
0
0
5
0
0
7
1
0
5
0
0
5
0
0
5
0
0
7
1
0

Advertisement

Table of Contents
loading

Table of Contents