Vehicle-floor Mount
Kohler' s mobile generator set can also be installed on
an open vehicle' s floor, or truck bed. Follow the same
guidelines as described in the compartment mount
section. Contact an authorized Kohler service dealer
with your specific application questions.
Extended-Shaft Option
If your generator set is equipped with the extended shaft
option, adequate space must be allowed at the
generator end of the set for an adapter, flexible coupling
and the equipment to be operated. The extended shaft
dimensions are 15/16"dia. x 1 3/4"long with a 1/4"key
way. Mounting flange conforms to SAE J609a, Flange
B. See Figure 6-13.
1
2
9
8
6
7
1. 1.88 (48)
2. Mounting flange to end of shaft
3. 30°typical
4. 3/8-16 UNC-2B .56 (14) deep 4 holes on 6.500 (165.10) diameter
bolt center
5. Pilot diameter: 5.749 (146.02)-5.751 (146.08)
6. 45°typical
7. Power takeoff and shaft dimensions
8. 0.2485 (6.31)-.2505 (6.36) keyway
9. Diameter 0.9365 (23.79)-.9375(23.81)
Figure 6-13. Extended Shaft Option
6-12 Installation
3
4
5
Customer must provide the adapter and flexible
coupling for the extended-shaft option.
Figure 6-14 shows a Kohler mobile generator set
mounted to a hydraulic pump. The generator set
equipped with the extended-shaft option can power
external equipment to the limit of the engine' s capacity.
Contact an authorized Kohler service dealer for your
generator set' s ability to power specific equipment.
Figure 6-14. Hydraulic pump
NOTE
1-921
TP-5393 9/93