Wiring Dc Power Inputs - Planet IGSW-24040T Quick Installation Manual

Industrial 24-port 10/100/1000mbps with 4 shared sfp managed gigabit switch
Hide thumbs Also See for IGSW-24040T:
Table of Contents

Advertisement

3. Wiring DC Power Inputs

The 6-contact terminal block connector on the rear panel of IGSW-24040T is used
for two DC redundant powers input. Please follow the steps below to insert the
power wire.
1. Insert positive / negative DC power wires into the contacts 1 and 2 for DC
POWER 1, or 5 and 6 for DC POWER 2.
CAUTION
Please refer to user's manual before
connect the DC wire.
DC Input Range: 36V~72V DC
2. Tighten the wire-clamp screws for preventing the wires from loosing.
The wire gauge for the terminal block should be in the range
between 12 ~ 24 AWG.
Note
4
DI 0
DI 1
DO 0
DO 1
GND
N/A
DC 1
Fault
DC 2
1
2
3
DC 1
Fault Alarm
+
-
AC POWER
100~240V AC
ON
50/60Hz
OFF
4
5
6
DC 2
+
-