Download Print this page

Technical Data - Saab 12 791 146 Installation Instructions

Cabin heater

Advertisement

2 12 795 083

Technical data

Cabin heater K2 (400 127 783) can be run at 600 W
(LOW) or 1500 W (HIGH).
Cabin heater K3 (400 127 791) can be run at 1250
W (LOW) or 2100 W (HIGH).
These outputs apply at -25°C and with a free flow of
air. The heater element regulates power output
depending on the ambient temperature and airflow
through the fan.
The cabin heater has a thermostatic shut-off that
cuts the power to the heater element and the fan
motor should the temperature exceed the permitted
limit. The thermostatic shut-off will trip if air circula-
tion is insufficient, such as if the intake or outlet grille
is covered. The fan will cease to operate if the shut-
off trips.
Cabin heater K2: To reset the thermostatic shut-off:
1 Unplug the heater. Allow the heater to cool.
2 Depress the black button located in the heater's
outlet grille.
WARNING
Tools must not be used as they can damage the
heater element or the thermal circuit breaker. This
can cause a short circuit and a fire.
You should hear a distinct click.
Cabin heater K3: The thermostatic shut-off cannot
be reset but must be replaced. Contact your reseller.
Saab 9-3, Saab 9-5