Toshiba RAS-18N3KCV Service Manual page 48

Hide thumbs Also See for RAS-18N3KCV:
Table of Contents

Advertisement

10-3. Indoor Unit
10-3-1. Installation Place
• A place which provides enough spaces around
the indoor unit as shown in the diagram.
• A place where there are no obstacle near the air
inlet and outlet.
• A place which allows easy installation of the
piping to the outdoor unit.
• A place which allows the front panel to be
opened.
• The indoor unit shall be installed so that the top of
the indoor unit is positioned at least 2 m in height.
CAUTION
• Direct sunlight on the indoor unit wireless
receiver should be avoided.
• The microprocessor in the indoor unit should
not be too close to r-f sources.
(For details, see the owner's manual.)
<Remote control>
• Should be placed where there are no obstacles,
such as curtains, that may block the signal.
• Do not install the remote controller in a place
exposed to direct sunlight or close to a heating
source, such as a stove.
• Keep the remote controller at least 1 m away from
the nearest TV set or stereo equipment.
(This is necessary to prevent image disturbances
or noise interference.)
• The location of the remote controller should be
determined as shown below.
(Side view)
Reception
range
Remote controller
Fig. 10-3-1
(Top view)
Indoor unit
Reception
range
Remote controller
10-3-2. Drilling a Hole and Mounting
Installation Plate
<Cutting a hole>
When install the refrigerant pipes from the rear.
35
120
The center of the pipe hole is the above arrow.
1. After determining the pipe hole position on the
installation plate (
at a slight downward slant to the outdoor side.
NOTE :
• When drilling into a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
<Mounting the installation plate>
17 0
To unit out line
240mm
85
Hook
Pipe hole
Indoor unit
– 47 –
FILE NO. SVM-12053
180
240
Pipe hole
∅65 mm
Fig. 10-3-2
ð
) drill the pipe hole (Ø65 mm)
Anchor bolt holes
Hook
To unit out line
240mm
To unit out line
35mm
To unit out line
120mm
240
180
120
35
23
0
Hook
7
Mounting
Thread
screw
Weight
Fig. 10-3-3
23mm
Pipe hole (∅65 mm)
1
Installation plate