Problem Area
Items to Inspect
Inspect the two camera flex
assembly connections to the circuit
board
If the issue has not been resolved !
If the issue is still not resolved!
4/000 21-1/FEA 209 544/123 A
©
Company Internal
Sony Ericsson Mobile Communications AB
Repair Action
•
If either connection is improperly
connected - Reestablish proper
connection
•
If one or both of the connections is
dirty or oxidized – Clean both halves
of the connection(s)
•
If any portion on the camera
assembly flex film is damaged –
replace the camera flex assembly
•
If either of the camera flex assembly
connections on the circuit board is
damaged – Send to a repair location
allowed to perform electrical repairs
on this product
•
Replace camera flex assembly if it
has not already been replaced
•
Send to a repair location allowed to
perform electrical repairs on this
product