Connecting Weld Output Cables - Miller Auto-Continuum 350 Owner's Manual

With insight core
Hide thumbs Also See for Auto-Continuum 350:
Table of Contents

Advertisement

5-3. Connecting Weld Output Cables

3
6
9
8
Tools Needed:
3/4 in. (19 mm) for output
terminal type connection
1
2
Front View
4
6
8
7
2/0 and larger double cables
!
!
!
Ensure all connections are tight.
Tab Connection
.
1
2
3
4
5
6
7
8
9
Remove supplied nut and bolt from weld
output terminal. Insert bolt through hole in
weld cable terminal and hole in weld output
terminal. Screw nut onto bolt until weld
cable terminal is tight against output termi-
nal. Torque to 45-55 ft lb (61-75 N·m).
5
7
8
9
Turn off power before connecting to
weld output tabs or receptacles.
Do not use worn, damaged, under-
sized, or repaired cables.
Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your
machine.
Do not place anything between weld
cable terminal and output tab. Make
sure that the surfaces of the weld cable
terminal and output tab are clean.
Negative (−) Output Terminal
Positive (+) Output Terminal
Correct Weld Cable Connection For
Single Feeder
Correct Weld Cable Connection For
2/0 And Larger Double Cables
Incorrect Weld Cable Connection
Weld Output Terminal Bolt
Nut
Weld Cable Terminal
Output Terminal
OM-273473 Page 17