Ventilation
To ensure adequate ventilation, a minimum
ventilation gap of 45mm is required from the
back of appliance to cabinet wall.
For bench top installation, minimum 5mm
ventilation gap is required on both sides of the
appliance.
If oven is installed below a hob, minimum 30mm
ventilation gap between hob and oven, or the
distance instructed in the hob manufacturer's
instruction manual is required. Follow the higher
distance if in doubt.
Securing the appliance
Connect the power supply cord. Do not turn on
the power mains.
Push the oven into the housing unit as far as the
oven trim and align it.
Open the oven door. Fix the oven in position
with 4(four) screws provided.
Check that it is correctly aligned.
Check that the door is free to open and close.
Turn on the power mains. The appliance must
only be operated when it has been built in to
avoid electric shock hazard.
Electrical connections
Connecting the supply cable to the power mains
Install a standardized plug corresponding to the
load indicated on the rating label attached to the
appliance.
If the appliance is being directly connected to the
power mains supply, an omnipolar circuit breaker
must be installed with a minimum gap of 3mm
between the contacts, suitable for the load
indicated and complying with current electrical
regulations (the earthing wire must not be
interrupted by the circuit breaker). The supply
cable must not come into contact with surfaces
with temperatures higher than 50
The installer must ensure that the correct
electrical connection has been made and that it is
compliant with local safety regulations.
Before connecting to the power supply, ensure that:
The appliance is correctly and efficiently earthed.
The socket can withstand the maximum power of
the appliance, and voltage within the value range
indicated on the rating label attached to the
appliance.
The basic safety requirement should be tested by
a qualified technician. Multiple plugs and
extension cables must not be used. Overloading
is dangerous and may cause a fire hazard.
Once the appliance has been installed, the power
supply and electrical socket must be easily
accessible.
The installer must ensure that the correct electrical
connection has been made and that it is compliant
with local safety regulations.
The manufacturer declines any liability should
these safety measures not be observed.
14