Carrier AquaEdge 23XRV Start-Up, Operation And Maintenance Instructions Manual page 25

High-efficiency variable speed screw chiller with greenspeed intelligence and pic iii controls 50/60 hz hfc-134a
Table of Contents

Advertisement

CCN
Start Chiller In CCN Control
Start Chiller in Local Control
Clear Alarms
STATUS
List the
Status Tables
• MAINSTAT
• STARTUP
• COMPRESS
• HEAT_EX
• POWER
• VFD_STAT
• ECON_EXV (P COMPRESSOR ONLY)
• COND_EXV (P COMPRESSOR ONLY)
• ICVC_PWD
Select a Status Table
NEXT
PREVIOUS
Select a Modification Point
PREVIOUS
NEXT
Modify a Discrete Point
START
STOP
ON
OFF
Modify an Analog Point
INCREASE
DECREASE
Modify Control Options
DISABLE
ENABLE
Display the COND_EXV Table
• CONDENSER EXV
• TARGET CONDENSER EXV
• COND EXV STEPS
• CONDENSER LIQUID LEVEL
• FINE TUNE ACTIVE?
• DISCHARGE SUPERHEAT
• EVAPORATOR APPROACH
• COND LEVEL SETPOINT
• COND LEVEL OUTPUT [V]
• COND LEVEL ERROR
• COND LEVEL INTEGRAL
• COND LEVEL OUTPUT [%]
• COND LEVEL RANGE
• COND EXV MAX MOVEMENT
Display the ECON_EXV Table
• ECON EXV POSITION
• TARGET ECONOMIZER EXV
• ECON EXV STEPS
• ECON SUPERHEAT SETPOINT
• ECON SUPERHEAT
• ECON SUPERHEAT ERROR
• ECONOMIZER SAT TEMP
• ECONOMIZER PRESSURE
• ECONOMIZER GAS TEMP
• VFD SPEED OUTPUT
NOTE: The ICVC menu structure and tables shown in this man-
ual are for Q/R Compressors CESR-131293-04 Version 4 and
for P Compressors CESR-131584-05 Version 2. This applies
throughout the manual.
DEFAULT SCREEN
LOCAL
RESET
MENU
Access Main Menu
SCHEDULE
SETPOINT
SERVICE
List the Schedules
SELECT
EXIT
SELECT
EXIT
RELEASE
ENTER
ENTER
RELEASE
ENTER
QUIT
Select a Time Period/Override
NEXT
Modify a Schedule Time
INCREASE
Add/Eliminate a Day
ENABLE
Fig. 27 — 23XRV ICVC Menu Structure
(SOFTKEYS)
(ENTER A 4-DIGIT PASSWORD)
1 1 1
1
Display The Setpoint Table
Select the Setpoint
NEXT
PREVIOUS
Modify the Setpoint
INCREASE
DECREASE
• OCCPC01S – LOCAL TIME SCHEDULE
• OCCPC02S – ICE BUILD TIME SCHEDULE
• OCCPC03S – CCN TIME SCHEDULE
Select a Schedule
NEXT
PREVIOUS
Override
PREVIOUS
SELECT
DECREASE
ENTER
DISABLE
ENTER
NEXT
25
List the Service Tables
Base Demand Limit
• LCL Setpoint
• ECL Setpoint
• Ice Build Setpoint
• Tower Fan High Setpoint
SELECT
EXIT
ENTER
QUIT
SELECT
EXIT
1
2
3
4
5
6
7
8
EXIT
(ANALOG VALUES)
EXIT
(DISCRETE VALUES)
EXIT
ALARM HISTORY
ALERT HISTORY
CONTROL TEST
CONTROL ALGORITHM STATUS
EQUIPMENT CONFIGURATION
VFD CONFIG DATA
EQUIPMENT SERVICE
TIME AND DATE
ATTACH TO NETWORK DEVICE
LOG OUT OF DEVICE
ICVC CONFIGURATION
PREVIOUS
SELECT
SEE NEXT PAGE
EXIT