Pcb Diagrams; Pcb Diagrams (Main) - Samsung NE58F9710WS Service Manual

Slide in range
Hide thumbs Also See for NE58F9710WS:
Table of Contents

Advertisement

5. PCB Diagrams

5. PCB Diagrams

5-1 PCB Diagrams (Main)

(This Document can not be used without Samsung's authorization)
No.
Parts Number
1
RY501
2
RY502
3
RY503
4
RY504
5
RY505
6
RY506
7
RY507
8
RY508
9
RY509
10
RY510
11
RY511
12
RY512
13
CN101
14
CN201
15
CN202
16
CN301
17
CN401
18
CN501
19
CN502
20
T501
21
T502
22
T503
23
T504
24
T505
25
T506
26
T507
27
T508
28
T509
Part Name
RY-Source Relay
Circuit is designed to have broil relay or convection relay worked after DLB relay is being worked by Double line break.
DLB Relay
(It will not be problem with reversing the order in inserting Red)
Broil-Heater Relay
"Broil relay(Ry503), Bake relay(Ry504), convection relay(Ry505) will be on-off
working by mi-com signal after DLB relay is worked.
Bake-Heater Relay
(Broil relay : It will not be problem with reversing the order in inserting Brown)
(Bake relay : It will not be problem with reversing the order in inserting Blue)
Conv-Heater Relay
WD-Heater Relay
This is Relay to control Warming Drawer-Heater.
WC-Heater Relay
This is Relay to control Warming Centor-Heater.
Conv-Fan-U Relay
This is relay which is connected with Conv. Fan.
Conv-Lamp-U Relay
This is relay which is connected with Conv-Lamp-Upper
Door Lock Relay
This is relay which is connected with door lock motor.
Oven-Fan-L Relay
This is relay which is connected with Oven-Fan-Low.
Oven-Lamp-L Relay
This is relay which is connected with Oven-Lamp-Low.
Power Connector
This is to supply power with SMPS.
Sub Communication Connector
This is connector which is connected with Sub PCB to communicate.
When do micom revision, connect to micom writer. And this connector which is connected with Touch PCB to
On Board Writing Connector
communicate.
Oven Sensing Connector
This connector which is connected with oven sensor.
Door Lock, Divider Connector
This is connector which is connected with Door plung switch and Door lock switch, divider switch.
Relay Connector
This connector which have Door plunger switch, upper lamp and relay of upper convection fan connected.
Relay Connector
This connector which have lower lamp and relay of lower convection fan connected
DLB Terminal
This is terminal to connect harness with DLB relay.
Broil Terminal
This is terminal to connect harness with Broil relay.
Bake Terminal
This is terminal to connect harness with Bake relay.
Convection-Heater Terminal
This is terminal to connect harness with convection-heater relay.
WD-Heater Terminal
This is terminal to connect harness with relay to get heater on warming drawer work.
WC-Heater Termainal
This is terminal to connect harness with relay to get heater on warming centor work.
Function and Rule
48

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ne58f9500ssNe58f9500ss/aa

Table of Contents