Philips MCW770 Service Manual page 14

Micro system
Hide thumbs Also See for MCW770:
Table of Contents

Advertisement

DISMANTLING INSTRUCTIONS
Dismantling the 5 Disc Tray Changer
• Dismantle top cover and cabinet side panels first.
• Remove 4 screws as shown in pictures 6 and 7.
• Raise the changer unit at the rear and pull it out of the set.
5 DISC TRAY CHANGER
3
5 DISC TRAY CHANGER
1
picture 6
2
picture 7
picture 8
4-2
Dismantling the Combi Board
• Dismantle top cover and cabinet side panels first.
• Remove 3 screws as shown in pictures 9.
• Remove 2 screws fixing the 5DTC.
It is advised to dismantle the 5DTC completely.
• Release 2 catches of the rear cabinet and move it backwards
to get access to the cooling fin.
• Remove 1 screw fixing the cooling fin to the bottom plate →
see picture 10.
• Release catches on front side as shown in picture 9 and fetch
Combi Board out of the set.
1
5
release
catches
metal screw M3
1
1
3
move rear cabinet
backwards
1
2
release catches
picture 9
4
loosen screw
to cooling fin
picture 10