SITE REQUIREMENTS - Page 6
FIG. 4 FLUE LENGTHS

ELECTRICITY SUPPLY

A 240 volts -~ 50Hz, single phase electricity supply fused to
3 amperes, must be provided in accordance with the latest
edition of the I.E.E. Wiring Regulations and any other local
regulations that may apply. The current rating of the wiring
to the boiler must exceed 3 amperes and have a cross
sectional area of at least 0.75mm
B56500 Table 16.
Maximum working head
Minimum working head on
Fully Pumped systems
Minimum circulating head
on Gravity systems
Gas supply pressure
Maximum Flow temperature
Electricity supply
Power consumption
Flow/Return connection
Supplied By www.heating spares.co Tel. 0161 620 6677
ALL MODELS REAR OR SIDE FLUEING
2
in accordance with

TECHNICAL DATA

30.5m (100 ft)
305mm (1 ft)
1.2m (4ft)
20mbar
0
82
C
240v~-50Hz fused
at 3A
80 watts
(excluding pump)
22mm copper on
30e, 40e models
28mm copper on
50e, 60e, 80e
models
STANDARD FLUE
SYSTEM
1 METRE FLUE
SYSTEM
The supply to the boiler and its associated equipment should
be controlled by an exclusive 3A fused double pole switch
(having at least 3mm contact separation in both poles) so that
complete isolation from the supply can be achieved to enable
servicing work to be carried out in safety.
Gas supply connection
Water Content
Appliance Weight-installed
Appliance Weight-lift
Appliance Weight-installed
Appliance Weight-lift
MAXIMUM
LENGTH 'X'
510mm
(20in)
955mm
(37in)
Rc. 1/2 (i/2in BSP
Female)
Models 30e, 40e
6.0 litre (1.32 gal)
Models 50e, 60e &
80e
6.5 litre (1.43 gal)
Models 30e, 40e
52kg (115 Ibs)
46kg (101 Ibs)
Models 50e, 60e &
80e
62kg (137 Ibs)
53kg (117 Ibs)