Automatic presser foot lifter initializing position

Mechanical adjustment
A
33
To adjust:
1. Remove the top cover.
2. Turn the power switch ON while pressing the Start/Stop
button and the Reverse stitch button. The LCD shows the
Factory Setting Mode. Press "Foot Sensor" key.
3. Turn the gear A (indicated with black arrow) with your hand
to raise the presser foot.
4. Place a 13 mm thick spacer between the presser foot and
the needle plate. Lower the presser foot on the spacer
firmly by turning the gear A.
5. Be sure that the both Sensors 1 and Sensor 2 show "H".
Press "Start" key on the touch panel.
* In case either Sensor 1 or Sensor 2 is not "H", turn the
adjusting screw (indicated with white arrow) clockwise
until the both Sensor 1 and Sensor 2 show "H".
6. Turn the adjusting screw counterclockwise until a beep
sound and the "OK" message is shown.

Hide quick links: