CY, MS, & MD

Low battery indications

Condition
Batteries low After credential PIN is pressed,
9 red blinks of Schlage button,
then normal indicator.
Battery
No LED or beeps
failure
Valid credentials do not grant
access

Battery failure mode

In the event of battery failure, the lock will fail As-Is (lock remains in current state, locked or
unlocked, until batteries are replaced).

Schlage button

Condition
Access denied
Valid PIN entered while lock in Freeze mode 12 red blinks indicating lockout
Factory default reset
Low battery indicator, AA batteries
Momentary unsecured access

Optional Inside Push Button (IPB)

Office Mode
Press IPB to lock
Press IPB to unlock
1 Unlocking the lock with the IPB will cause the lock to remain unlocked until the IPB is depressed again.
!
Plug MUST Be on Right
Indicator
Action
1
993
Replace batteries immediately to avoid
battery failure. Lock is intended to operate
for 500 cycles in low battery condition.
Replace batteries immediately.
Mechanical override key must be used to
unlock the lock.

LED reference

2 red blinks
One-second solid green with one-second beep
9 left red blinks
1 green blink, then one red blink on relock
1 red blink
1 green blink