(3) Control Settings
Power Switch
.............................................. ON
Fader Control
........................... Center Position
Balance Control
....................... Center Position
Treble Control
.......................... Center Position
Bass Contro
............................. Center Position
MX
................................................... Non Effect
(4) Adjustment Procedures
Connectio
Step
Description
Signal Meter
Auto
1
Figure 3
Adjustment
(FM)
Signal Meter
Auto
2
Figure 4
Adjustment
(MW)
Signal Generator
Dial Control
n
87.5MHz ,
(1)
26dBµ
(Mod. OFF)
87.5MHz ,
(2)
26dBµ
(Mod. OFF)
87.5MHz ,
(3)
21~23dBµ
(Mod. OFF)
87.5MHz ,
(4)
26dBµ
(Mod. OFF)
999kHz ,
(1)
34dBµ
(Mod. OFF)
999kHz ,
(2)
34dBµ
(Mod. OFF)
999kHz ,
(3)
29~31dBµ
(Mod. OFF)
999kHz ,
(4)
34dBµ
(Mod. OFF)
- 9 -
Band Switch
.............................. FM/MW/LW
T-CORR
...................................... Non Effect
EQ
....................................................... FLAT
DEMO
................................................... OFF
Others
................................................... OFF
Test Point /
P .W.Board
Coordinates
TP012
Auto Adjustment :
(3-F)
After setting up of Signal Genarator,
87.5MHz
TP011
short GND and TP011 (Pull-Down)
(3-F)
for 2~3 seconds
Proceed same Auto Adjustment of step
(1) under step (2)
TP012
(SPEC) TP012 : 1.5±0.1V
(3-F)
(SPEC) TP012 : others 1.5±0.1V
87.5MHz
TP011
(3-F)
NOTE : NG : Proceed same Auto
TP012
(3-F)
Proceed same Auto Adjustment of step
87.5MHz
TP011
(1) under step (3)
(3-F)
TP012
(3-F)
Proceed same Auto Adjustment of step
87.5MHz
TP011
(1) under step (4)
(3-F)
TP012
Auto Adjustment :
(3-F)
After setting up of Signal Genarator,
999kHz
TP011
short GND and TP011 (Pull-Down)
(3-F)
for 2~3 seconds
Proceed same Auto Adjustment of step
(1) under step (2)
TP012
(SPEC) TP012 : 1.0±0.1V
(3-F)
(SPEC) TP012 : others 1.0±0.1V
999kHz
TP011
(3-F)
NOTE : NG : Proceed same Auto
TP012
(3-F)
Proceed same Auto Adjustment of step
999kHz
TP011
(1) under step (3)
(3-F)
TP012
(3-F)
Proceed same Auto Adjustment of step
999kHz
TP011
(1) under step (4)
(3-F)
CDA-9831R
Adjustment
OK
NG
Adjustment of step (1)
under step (3)
OK
NG
Adjustment of step (1)
under step (3)

Advertisement

loading