3 Alignments and Adjustments
3-4 Bordeaux Micom Update
3-4-1 Installing G-Probe
1. Uncompress GProbe5.1.0.18.zip.
2. Run GProbe5.1.0.18.exe.
3. The files are created in the C: Program Files Genesis Microchip GProbe 5 folder.
4. Copy the ispoak_spi.hex file to the C: Program Files Genesis Microchip GProbe 5 folder.
5. Copy the bordeaux.txt, torino.txt file to the C: Program Files Genesis Microchip GProbe 5 folder.
(bordeaux.txt or torino.txt have the command list to download. The file name should be changed.)
6. Execute the 'Gprobe 5'
7. Click the 'connection settings' button.
8. Change the connection from 'Serial' to 'Parallel'
3-7