KRC-225/235/265/265S
MICROCOMPUTER'S TERMINAL DESCRIPTION
Terminal Description ( IC1 : X14-6850-XX)
Pin No.
Pin Name
61
ACC DET
62
B.U. DET
63
S METER
64
PANEL
65
GND
66
GND
67
HOLD
68
VDD
69
GND
70
GND
71,72
-
73
VDD
74
GND
75
GND
76
VSS
77,78
-
79
GND
80
XOUT
6
I/O
Description
I
ACC detection input
I
Momentary power down detection input
I
S-meter input from the F/E
I
Panel detaching detection input
I
-
I
-
I
MI-COM. HOLD input
-
VDD connection terminal
I
-
I
-
O
-
-
Positive power supply connection terminal Connected to B.U. 5V lines.
I
-
I
-
-
Ground connection terminal
O
-
-
TEST terminal 1
O
Main clock resonator connection terminal
Processing Operation
Hi : ACC ON
Hi : When momentary power down detected or
B.U. OFF, Lo : B.U. ON
Lo : Panel not detached
Connected to GND lines.
Connected to GND lines.
Lo : Hold
Connected to B.U. 5V lines.
Connected to GND lines.
Connected to GND lines.
N.C.(Not used)
Connected to GND lines.
Connected to GND lines.
Connected to GND lines.
N.C.(Not used)
Connected to GND lines.