Emissions

The United States Environmental Protection
Agency
(US
EPA)
Resources Board (CARB), for engines/equip-
ment certified to California standards) requires
that this engine/equipment complies with
exhaust and evaporative emissions stan-
dards. Locate the emissions compliance decal
on the engine to determine applicable stan-
dards. For emissions warranty information,
please reference the included emissions war-
ranty. It is important to follow the maintenance
specifications in the manual to ensure that the
engine complies with the applicable emissions
standards for the duration of the product's life.
TABLE 2. Product Specifications
Generator Specifications
Rated Power
Surge Power
Rated AC Voltage
Rated AC Load
Current @ 240V
Current @ 120V
Rated Frequency
Phase
Generator Dry Weight (assembled)
** Operating Temperature Range: -18 deg. C (0 deg. F) to 40 Deg. C (104 Deg. F). When operated
above 25 deg. C (77 deg. F) there may be a decrease in power.
** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambi-
ent temperature, altitude, engine condition, etc.. Maximum power decreases about 3.5% for each
1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60°
F) ambient temperature.
Engine Specifications
Displacement
Spark Plug Part No.
Spark Plug Type
Spark Plug Gap
Gasoline Capacity
Oil Type
Oil Capacity
Run Time at 50% Load
* Go to Generac.com or contact an IASD for replacement parts.
Owner's Manual for Portable Generator
(and
California
Air
3.3 kW**
3.75 kW
120/240
13.75 Amps**
27.5 Amps**
60 Hz @ 3600 RPM
Single Phase
111.4 lbs. (50.5 kg)
208 cc
0H33750169
F6TC, NGK BP6IS or Champion RN11YC
0.030 inch (0.76 mm)
3.35 gal (12.7 L)
See Chart in the
0.634 qt (0.6 L)
10.2 Hours
Add Engine Oil