HP ProLiant ML370 Maintenance And Service Manual page 83

Generation 3
Hide thumbs Also See for ProLiant ML370:
Table of Contents

Advertisement

LED Indicators and Switches
Table 4-3: Hot-Plug SCSI Hard Drive LED Combinations
Activity LED
On
On
Flashing
Off
Off
Off
On or
flashing
4-4
Online LED
Fault LED
Off
Off
Flashing
Off
Flashing
Flashing
Off
Off
Off
On
On
Off
On
Off
HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide
Status
Do not remove the drive. Removing a drive
during this process causes data loss.
The drive is being accessed and is not
configured as part of an array.
Do not remove the drive. Removing a drive
during this process causes data loss.
The drive is rebuilding or undergoing capacity
expansion.
Do not remove the drive. Removing a drive
during this process causes data loss.
The drive is part of an array being selected by
the Array Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
OK to replace the drive online if a predictive
failure alert is received and the drive is attached
to an array controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, a powered-on
controller is not accessing the drive.
-Or-
The drive is configured as an online spare.
OK to replace the drive online.
The drive has failed and has been placed offline.
OK to replace the drive online if a predictive
failure alert is received, provided that the array is
configured for fault tolerance and all other drives
in the array are online.
The drive is online and configured as part of an
array.
OK to replace the drive online if a predictive
failure alert is received, provided that the array is
configured for fault tolerance and all other drives
in the array are online.
The drive is online and being accessed.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents