Maintenance Of Motors; Troubleshooting - Dyna-Glo WHF100 Important Instructions Manual

Wall heater fan
Table of Contents

Advertisement

Available languages

Available languages

MAINTENANCE OF MOTORS

WARNING: Make sure all power to the appliance is turned OFF
before proceeding.
Always disconnect the appliance from the main power supply and allow it to
cool before any servicing operation. The motor used on the fan is pre-lubricated
for extended bearing life and requires no further lubrication. However, periodic
cleaning/vacuuming of the appliance around the air intake and exhaust, as well
as the fan is recommended. For heavy or continuous use, periodic cleaning
must be done more frequently. If the heater blows alternating cold and warm air,
check the fan for free movement and for debris restricting air flow. If the fan does
not move freely, the unit must be turned off and the fan replaced immediately in
order to prevent further damage to the unit.

Troubleshooting

PROBLEM
Fan is not
spinning.
Fan is making a
loud noise.
POSSIBLE CAUSE
1. There is no power to
the fan.
2. Fan is set to
"AUTO".
3. Fan motor is bad.
1. Fan housing or
blades are dirty.
2. Fan rotation is
blocked.
3. Defective Fan.
CORRECTIVE ACTION
1. Verify fan is plugged in and
set to "MAN" or "AUTO".
2. Allow 5-10 minutes for fan
to engage.
3. Replace fan.
1. Clean fan and fan housing.
2. Verify wiring is not in fan path.
3. Replace fan.
5
Printed in China

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents